High Voltage Surge Protector for Customizable Applications and Needs

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • High Voltage Surge Protector for Customizable Applications and Needs
  • High Voltage Surge Protector for Customizable Applications and Needs
  • High Voltage Surge Protector for Customizable Applications and Needs
  • High Voltage Surge Protector for Customizable Applications and Needs
  • High Voltage Surge Protector for Customizable Applications and Needs
  • High Voltage Surge Protector for Customizable Applications and Needs
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the revolutionary Zinc Oxide Arrester from Beierbian Group Co., Ltd—a remarkable advancement in lightning protection technology tailored precisely for 10kV power distribution systems. This state-of-the-art device stands as a beacon of innovation, ingeniously crafted with a zinc oxide valve column. Enhanced by the deliberate positioning of upper and lower electrodes, it is expertly encased in high-quality silicone rubber. This sophisticated configuration boasts unparalleled features:

  1. Experience the groundbreaking design that proficiently addresses and overcomes sealing issues that have traditionally troubled arrester systems. By seamlessly integrating the core and jacket into a cohesive, streamlined unit, it thoroughly eradicates potential cavities that might lead to detrimental internal breathing issues. Through this masterful engineering, it adeptly surmounts the intricate technical challenges of preventing moisture ingress in the internal components, ensuring exceptional performance.
  2. Showcasing a robust core with an extraordinary ability to endure internal overvoltage, this arrester epitomizes superior engineering. It features remarkable resistance to aging, ensuring consistent performance and unwavering protection year after year, providing users with assurance of its enduring reliability and effectiveness.

Incorporating a uniquely engineered valve plate combined with optimized core parameters, this device guarantees that the core can effectively manage challenges such as arc grounding, PT resonance, and a wide spectrum of operational overvoltages. It performs with unmatched reliability, confidently maintaining its function under normal line voltage and enduring 2.5 to 3 times power frequency overvoltage. Its voltage withstand duration not only aligns with but surpasses international standards by a factor of 1 to 3 orders of magnitude, offering unparalleled safety and outstanding operational longevity.
High Voltage Surge Protector for Customizable Applications and Needs

Detailed Photos

High Voltage Surge Protector for Customizable Applications and Needs

High Voltage Surge Protector for Customizable Applications and Needs
High Voltage Surge Protector for Customizable Applications and Needs
High Voltage Surge Protector for Customizable Applications and Needs
High Voltage Surge Protector for Customizable Applications and Needs
High Voltage Surge Protector for Customizable Applications and Needs
High Voltage Surge Protector for Customizable Applications and Needs

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Meticulously engineered for impeccable performance in both indoor and outdoor environments, offering versatility and reliability;

Remarkably assures seamless operation at altitudes reaching up to a breathtaking 3000 meters;

Designed to endure extreme ambient temperature fluctuations, ranging from a frigid -40C to a balmy +60C;

Ingeniously crafted to accommodate power supply frequencies varying from a consistent 48Hz to a vibrant 62Hz;

Secures the power frequency voltage applied between terminals within optimal thresholds, ensuring long-lasting and dependable performance.

Engineered to withstand seismic forces not exceeding 8 degrees, fortifying resilience during earthquakes.

Capable of enduring robust outdoor wind speeds soaring up to 35 meters per second;

Note:

Facing circumstances that surpass these standard operational parameters? Our dedicated team is eager to collaborate and engineer custom-tailored solutions.

Main Technical Parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Demonstrating an enduring and robust Polymeric composition.

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Equipped with advanced Porcelain Series Gap specifications for enhanced functionality.

Installation

(1) Prior to installation, it is essential to check the nameplate to confirm that the arrester's system rated voltage aligns precisely with the system voltage at the installation location;

(2) Offers installation versatility with options for suspension or vertical setups. For vertical installations, ensure that the arrester is not employed as a load-bearing insulator;

(3) Optimize the length of lead wires to uphold protection efficiency and avert unnecessary stress on the apparatus.

Test

  • lTo bolster operational reliability, preventive tests are recommended every 4-5 years. These evaluations should focus on measuring U1mA at both terminals of the DC 1mA arrester.
  • lBefore installation, ensure the U1mA voltage is at least 97% of the initial factory value and meticulously record this data for precision.
  • lDuring preventive maintenance, it is crucial to maintain the U1mA voltage above 26kV to ensure continued efficiency.
  • lNote: During tests, it is vital to minimize harmonic components in the DC power supply, as distorted waveforms can result in low U1mA readings.
  • lOur newly developed 10kV synthetic insulated zinc oxide arrester for power distribution has successfully passed stringent lab tests, showcasing its consistent performance under outdoor line voltage for an impressive 15 months. These findings highlight the superior quality of the jacket, the arrester’s structural integrity, and the unwavering stability of its core. Combined with annual performance data from 2,000 units, this product promises unsurpassed protection, significantly decreased failure rates, and a maintenance-free experience throughout its lifecycle.High Voltage Surge Protector for Customizable Applications and Needs
Certifications

High Voltage Surge Protector for Customizable Applications and Needs

Company Profile

High Voltage Surge Protector for Customizable Applications and Needs

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier