Customization: | Available |
---|---|
Type: | Power Source Arrester |
Structure: | Zinc Oxide Arrester |
Still deciding? Get samples of US$ 35/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd - an exceptional, fully sealed, and remarkably dependable innovation in lightning protection tailored for 10kV power distribution systems. This cutting-edge device is meticulously engineered, featuring a state-of-the-art zinc oxide valve column paired with intricately designed upper and lower electrodes. Encapsulated entirely in premium-grade silicone rubber, it boasts unrivaled attributes that redefine industry benchmarks:
Utilizing a specially crafted valve plate alongside optimized core parameters, this device ensures exceptional protection. The core is expertly designed to handle challenges such as arc grounding, PT resonance, and an array of operational overvoltages. It performs with unmatched reliability under line voltage, while enduring 2.5 to 3 times power frequency overvoltage. Its voltage withstand duration exceeds international standards by an impressive 1 to 3 orders of magnitude, offering unparalleled safety and operational longevity, establishing it as a benchmark for high-performance protection solutions.
Main Characteristics Of Jacket Materials And Product Usage Environment:
Item |
Unit |
Norm |
Shore Hardness A |
/ |
60 |
Tensile Strength |
mpa |
≥35 |
Breaking Elongation |
% |
≥250 |
Oxygen Index |
/ |
45 |
Resistivity |
Ω.m |
≥1×1013 |
Breakdown Strength |
MV/m |
≥25 |
Tracking |
kV |
4.5 |
Durability |
Not less than 20 years |
Working Environment:
Our expertly engineered surge arrester is designed to deliver impeccable performance in any scenario, whether it's deployed indoors or braving the elements outdoors.
It confidently thrives at astounding altitudes, soaring up to an awe-inspiring 3000 meters without compromising functionality.
This device is crafted to operate seamlessly across a vast temperature range, from a chilling -40°C to a comfortably warm +60°C, effortlessly adapting to diverse climates.
Meticulously designed for compatibility with power supply frequencies from a stable 48Hz to a dynamic 62Hz, ensuring seamless integration and performance.
Ensures the power frequency voltage between terminals remains within optimal limits, promoting sustainable and reliable long-term operation.
Engineered to endure seismic activities up to 8 degrees in intensity, providing unwavering stability and security.
Built to resist formidable outdoor wind speeds of up to 35 meters per second, it promises steadfast endurance against the harshest weather conditions.
Note:
If your requirements surpass the standard operational parameters, our dedicated team is poised to offer bespoke solutions precisely tailored to your unique needs.
Main Technical Parameters
Model |
Nominal Voltage (rms) |
Rated Voltage Of Arrester (rms) |
Continuous Operating Voltage (rms) |
DC 1mA reference voltage |
The residual voltage under nominal discharge current |
Steep wave impact residual voltage |
2ms square wave flow capacity |
Operation Place |
YH5WS-3.8/17 |
3 |
3.8 |
2.0 |
7.5 |
17.0 |
19.6 |
100 |
Distribution Type |
YH5WS-5/15 |
3 |
5 |
4.0 |
7.5 |
15.0 |
17.3 |
150 |
|
YH5WS-7.6/30 |
6 |
7.6 |
4.0 |
15.0 |
15.0 |
34.5 |
100 |
|
YH5WS-10/30 |
6 |
10 |
8.0 |
15.0 |
30.0 |
34.6 |
150 |
|
YH5WS-12.7/50 |
10 |
12.7 |
10 |
26.0 |
50.0 |
57.5 |
100 |
|
YH5WS-16.5/50 |
10 |
16.5 |
12.7 |
26.0 |
50.0 |
57.5 |
100 |
|
YH5WS-17/50 |
10 |
17 |
13.6 |
26.0 |
50.0 |
57.5 |
150 |
|
YH5WS-17/45 |
10 |
17 |
13.6 |
25.0 |
45.0 |
/ |
250 |
|
YH10WS-17/45 |
10 |
17 |
13.6 |
25.0 |
45.0 |
/ |
400 |
|
YH5WZ-5/13.5 |
3 |
5 |
4.0 |
7.2 |
13.5 |
15.5 |
200 |
Power Station Type |
YH5WZ-7.6/27 |
6 |
7.6 |
4.0 |
14.4 |
27.0 |
31.0 |
150 |
|
YH5WZ-10/27 |
6 |
10 |
8.0 |
14.4 |
27.0 |
31.0 |
200 |
|
YH5WZ-42/134 |
35 |
42 |
23.4 |
73 |
134 |
154 |
150 |
|
YH5WZ-12.7/45 |
10 |
12.7 |
6.6 |
24.0 |
45.0 |
51.8 |
150 |
|
YH5WZ-16.5/45 |
10 |
16.5 |
13.2 |
24.0 |
45.0 |
51.8 |
150 |
|
YH5WZ-17/45 |
10 |
17 |
13.6 |
24.0 |
45.0 |
51.8 |
200 |
|
YH5WZ-51/134 |
35 |
51 |
40.8 |
73.0 |
134 |
154 |
400 |
|
YH10WZ-17/45 |
10 |
17 |
13.6 |
24.0 |
45.0 |
51.8 |
200 |
|
YH10WZ-51/134 |
35 |
51 |
40.8 |
73.0 |
134 |
154 |
400 |
|
YH5WR-5/13.5 |
3 |
5 |
4.0 |
7.2 |
13.5 |
/ |
400 |
Capacitive Type |
YH5WR-7.6/27 |
6 |
7.6 |
4.0 |
13.8 |
27.0 |
/ |
400 |
|
YH5WR-10/27 |
6 |
10 |
8.0 |
14.4 |
27.0 |
/ |
400 |
|
YH5WR-12.7/45 |
10 |
12.7 |
6.6 |
23.0 |
45.0 |
/ |
400 |
|
YH5WR 17/45 |
10 |
17 |
13.6 |
24.0 |
45.0 |
/ |
400 |
|
YH5WX-51/134 |
35 |
51 |
40.8 |
73 |
134.0 |
154 |
400 |
Line type |
YH1.5W-30/80 |
35 |
30 |
24 |
44 |
80.0 |
/ |
600 |
Neutral Type |
Note: Featuring a durable Polymeric construction, this product exemplifies resilience and robust longevity.
Model |
Nominal Voltage (rms) |
Rated Voltage Of Arrester (rms) |
Continuous Operating Voltage (rms) |
DC 1mA Reference Voltage |
The Residual Voltage Under Nominal Discharge Current |
Steep Wave Impact Residual Voltage |
2ms Square Wave Flow Capacity |
Operation Place |
Y5WS-5/15 |
3 |
5 |
4.0 |
7.5 |
15.0 |
17.3 |
150 |
Distribution Type |
Y5WS-7.6/30 |
6 |
7.6 |
4.0 |
15.0 |
15.0 |
34.5 |
100 |
|
Y5WS-10/30 |
6 |
10 |
8.0 |
15.0 |
30.0 |
34.6 |
150 |
|
Y5WS-12.7/50 |
10 |
12.7 |
10 |
26.0 |
50.0 |
57.5 |
100 |
|
Y5WS-16.5/50 |
10 |
16.5 |
12.7 |
26.0 |
50.0 |
57.5 |
100 |
|
Y5WS-17/50 |
10 |
17 |
13.6 |
26.0 |
50.0 |
57.5 |
150 |
|
Y5WZ-5/13.5 |
3 |
5 |
4.0 |
7.2 |
13.5 |
15.5 |
200 |
Power Station Type |
Y5WZ-7.6/27 |
6 |
7.6 |
4.0 |
14.4 |
27.0 |
31.0 |
150 |
|
Y5WZ-10/27 |
6 |
10 |
8.0 |
14.4 |
27.0 |
31.0 |
200 |
|
Y5WZ-42/134 |
35 |
42 |
23.4 |
73 |
134 |
154 |
150 |
|
Y5WZ-12.7/45 |
10 |
12.7 |
6.6 |
24.0 |
45.0 |
51.8 |
150 |
|
Y5WZ-16.5/45 |
10 |
16.5 |
13.2 |
24.0 |
45.0 |
51.8 |
150 |
|
Y5WZ-17/45 |
10 |
17 |
13.6 |
24.0 |
45.0 |
51.8 |
200 |
|
Y5WZ-51/134 |
35 |
51 |
40.8 |
73.0 |
134 |
154 |
400 |
|
Y5WR-5/13.5 |
3 |
5 |
4.0 |
7.2 |
13.5 |
/ |
400 |
Capacitive Type |
Y5WR-7.6/27 |
6 |
7.6 |
4.0 |
13.8 |
27.0 |
/ |
400 |
|
Y5WR-10/27 |
6 |
10 |
8.0 |
14.4 |
27.0 |
/ |
400 |
|
Y5WR-12.7/45 |
10 |
12.7 |
6.6 |
23.0 |
45.0 |
/ |
400 |
|
Y5WR-17/45 |
10 |
17 |
13.6 |
24.0 |
45.0 |
/ |
400 |
|
Y1.5W-0.28/1.3 |
0.22 |
0.28 |
0.24 |
0.6 |
1.3 |
/ |
75 |
Low Voltage |
Y1.5W-0.5/2.6 |
0.38 |
0.5 |
0.24 |
1.2 |
2.6 |
/ |
75 |
|
Note:Porcelain |
Model |
Nominal Voltage |
Rated Voltage Of Arrester |
The Wave Front Steepness Of The Shock Discharge |
DC 1mA Reference Voltage kV Not Less Than |
1.2/50 Impulse Discharge Voltage Not Greater Than |
Wavefront Impulse Discharge Voltage
kV Not Greater Than |
The Residual Voltage Under Nominal Discharge Current 8/20μs
kV Not Greater Than |
2000μs Square Wave Flow Capacity |
4/10μs Impulse Current Capacity |
Y5CS-7.6/27 |
6 |
7.6 |
63 |
16 |
35 |
43.8 |
27 |
75 |
25 |
Y5CZ-7.6/24 |
6 |
7.6 |
63 |
16 |
30 |
37.5 |
24 |
150 |
40 |
Y5CS-12.7/45 |
10 |
12.7 |
106 |
26 |
50 |
62.5 |
45 |
75 |
25 |
Y5CS-12.7/41 |
10 |
12.7 |
106 |
26 |
45 |
56.5 |
41 |
200 |
40 |
Y5CZ-42/124 |
35 |
42.0 |
343 |
82 |
134 |
168 |
124 |
200 |
40 |
Note: The inclusion of a Porcelain Series Gap specification adds a touch of sophistication and advanced functionality.
Installation
(1) Prior to installation, verify the nameplate to ensure the arrester's system rated voltage aligns with the system voltage at the designated installation point.
(2) Offers flexible installation options with both suspension and vertical mounting. For vertical setups, ensure the arrester is not used as a load-supporting insulator.
(3) Optimize lead wire lengths to maximize protective efficiency and minimize stress on your equipment.
Test