Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, affectionately referred to as 'fuse', stands at the forefront of modern protection technology for outdoor overhead distribution systems. Operating at a dependable frequency of 50Hz and accommodating an impressive voltage range of 10kV up to 40.5kV, this fuse is an indispensable guardian against overloads and short circuit faults. Seamlessly integrated into power lines, the fuse remains steadfast and locked under normal conditions. When adversity strikes, the fault current dramatically activates the fuse, releasing its grip, swiftly disengaging the fuse tube, and effectively isolating the circuit. This critical operation ensures the utmost safety and protection for both line maintenance and electrical equipment. Enhanced with an elastic contact and an arc extinguishing cover, the load-type fuse elevates its functionality by managing the opening and closing of load currents within power systems with remarkable precision.
The fuse stands compliant with stringent technical standards, including GB/T 15166.3-2008 for high voltage AC fuses, Part 3: injection fuses, and DL/T 640-1997 for outdoor AC high voltage drop tested fuses. It adheres to comprehensive ordering technical conditions that guarantee operational excellence.
Working Environment:
Ambient temperature: Ranges from a brisk -40ºC to a warm +40ºC, catering to diverse climate conditions.
Relative humidity: Withstands a daily average humidity of up to 95%, and maintains resilience with a monthly average not exceeding 90%.
Altitude: Efficiently operates at elevations up to 3000 meters above sea level.
Outdoor wind speed: Designed to resist winds reaching speeds of up to 34 meters per second.
Installation site: Requires a setting free from fire, explosion hazards, and chemical corrosive gases, while ensuring the space is well-ventilated for optimal performance.
Note: Should the standard operating conditions be exceeded, a bespoke agreement can be arranged through direct negotiation with our company.
Technical parameters
Note: We provide the flexibility to tailor our product offerings to meet specific user requirements, ensuring a perfect fit for your application.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |