The ZW32-12 outdoor high voltage vacuum circuit breaker, fondly referred to as the 'circuit breaker,' is a pinnacle of outdoor distribution switchgear innovation, specifically engineered to function at an impressive rated voltage of 12kV, backed by a resilient three-phase AC of 50Hz. This multifunctional circuit breaker expertly manages the interruption and reconnection of load current, overload current, and short circuit current within the power grid. It features state-of-the-art overload and short circuit protection, effortlessly fulfilling rigorous control and measurement requirements while offering sophisticated remote control and monitoring capabilities. Widely embraced across substations, industrial landscapes, and mining enterprise distribution systems, it provides unrivaled control and operation, making it the perfect fit for settings with frequent operational demands.
Structural Features:
Meticulously crafted, the circuit breaker exhibits a refined three-phase pillar dry design;
Designed with a fully enclosed structure, it ensures exceptional sealing, extraordinary moisture resistance, and superior anti-condensation properties, making it an impeccable choice for high-temperature and humid climates;
Utilizes cutting-edge vacuum arc extinguishing technology to deliver exceptional insulation reliability;
Offers impeccable opening and closing performance, guaranteeing safety without the risk of combustion or explosion;
Compact and lightweight, it requires zero maintenance and offers a remarkable lifespan;
Offers operational versatility with manual, electric, or remote control options;
The operating mechanism is expertly sealed at the base of the switch box, providing robust protection against outdoor environmental corrosion;
Boasts a novel, minimalist design with a dynamic mechanism that ensures reliable performance, a compact form, and an incredible service life of up to 10,000 cycles.
Main Technical Parameters:
No |
Name |
Unit |
Data |
|||
1 |
Rated voltage |
kV |
12 |
|||
2 |
Rated current |
A |
630 |
1250 |
||
3 |
Rated frequency |
Hz |
50 |
|||
4 |
Rated insulation level |
1min power frequency withstand voltage |
Dry test |
/ |
42/48(fracture) |
|
Wet test |
34 |
|||||
Secondary circuit to ground |
2 |
|||||
Lightning impulse withstand voltage (peak value) |
75/85(fracture) |
|||||
5 |
Rated short circuit making current (peak value) |
kA |
50 |
63 |
||
6 |
Rated short time withstand current |
kA |
20 |
25 |
||
7 |
Rated peak withstand current |
kA |
50 |
63 |
||
8 |
Breaking times of rated short circuit breaking current |
Times |
30 |
|||
9 |
Rated short circuit duration |
s |
4 |
|||
10 |
Rated operating voltage and rated voltage of auxiliary circuit |
V |
DC220,AC220 ,AC/DC220 |
|||
11 |
Rated operation sequence |
/ |
Off-0.3s-on-off-180s-on-off |
|||
12 |
Rated current of over current trip |
A |
5 |
|||
13 |
Mechanical life |
second |
10000 |
|||
14 |
Allowable wear accumulative thickness of moving and static contacts |
mm |
3 |
|||
15 |
Rated current of over current release |
A |
5 |
|||
16 |
Current ratio of current transformer |
/ |
200/5 400/5 600/5 |
|||
17 |
Contact opening distance |
mm |
9±1 |
|||
18 |
Contact overtravel |
mm |
2±0.5 |
|||
19 |
Average opening speed |
m/s |
1.2±0.3 |
|||
20 |
Average closing speed |
m/s |
0.6±0.2 |
|||
21 |
Opening time |
ms |
≤40 |
|||
22 |
Closing time |
ms |
20~45 |
|||
23 |
Closing bounce time |
ms |
≤2 |
|||
24 |
Asynchrony of three phase closing and opening |
mm |
≤2 |
|||
25 |
Three phase circuit resistance |
μΩ |
≤80 Band isolation≤120 |