(H) RW(F) series outdoor high voltage AC drop fuse, affectionately known as the 'fuse', is expertly designed for deployment in outdoor overhead distribution systems with a rated frequency of 50Hz and a rated voltage of 10kV (12/15/35/40.5). This fuse stands as a guardian of circuit integrity, vigilantly safeguarding electrical equipment against the perils of overload or short circuit faults within a power system. Under normal operation, the fuse is seamlessly integrated in series within the power line, maintained in a tensioned state with a secure movable joint. Upon the occurrence of a fault, the fault current gracefully triggers the fuse, liberating the movable joint, swiftly dropping the fuse tube, and effectively severing the circuit. This action ensures paramount safety and protection, facilitating maintenance of the line and equipment. Enhancing the ordinary type, the load type fuse boasts an elastic contact and arc extinguishing cover, adeptly managing the opening and closing of load currents within the power system.
The fuse adheres to rigorous technical standards, including GB / T 15166.3 - 2008 high voltage AC fuses - Part 3: injection fuses, and DL / T 640 - 1997 outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions, guaranteeing superior reliability and performance.
Working Environment:
Ambient temperature: Ranges from a frosty -40°C to a warm +40°C;
Relative humidity: Daily average does not exceed 95%, and the monthly average remains below 90%;
The operational altitude is thoughtfully capped at 3000 meters, ensuring optimal performance;
Outdoor wind speed should ideally not surpass 34 meters/second, maintaining environmental stability;
Installation site: Must be free of fire, explosion hazards, chemical corrosive gases, and should be well-ventilated to ensure safety and efficiency.
Note: Should the conditions for normal use be exceeded, users are encouraged to engage in discussion with the company to explore tailored solutions.
Technical parameters
Note: Our company is equipped to supply products meticulously tailored to the specific requirements and needs of our valued users.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |