Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of US$ 35/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs
  • Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs
  • Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs
  • Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs
  • Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs
  • Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Presenting the Zinc Oxide Arrester from Beierbian Group Co., Ltd—a groundbreaking, fully sealed, and exceptionally reliable lightning protection solution specifically engineered for 10kV power distribution systems. This state-of-the-art device is meticulously designed with a zinc oxide valve column, paired with upper and lower electrodes, all expertly encapsulated in silicone rubber, which endows it with extraordinary features:

  1. This pioneering design triumphantly resolves the sealing challenges that have traditionally plagued arresters. By ingeniously integrating the core and jacket into a cohesive, compact unit, it eliminates any cavities that could lead to internal breathing issues, thus astutely circumventing the technical obstacles related to moisture ingress within internal components.
  2. With a sturdy core built to withstand significant internal overvoltage, this arrester exemplifies outstanding aging resistance, guaranteeing consistent performance and steadfast protection over the years.

Employing a specially designed valve plate along with finely tuned core parameters, this device ensures the core endures challenges such as arc grounding, PT resonance, and a range of operational overvoltages. It operates with unparalleled dependability under line voltage and withstands 2.5 to 3 times power frequency overvoltage. Its voltage withstand duration exceeds international standards by 1 to 3 orders of magnitude, offering unmatched safety and operational longevity.
Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs

Detailed Photos

Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs

Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs
Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs
Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs
Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs
Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs
Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Expertly crafted for flawless functionality in both indoor and outdoor settings, ensuring reliable performance wherever needed;

Operates efficiently at impressive altitudes soaring up to 3000 meters, maintaining its effectiveness in elevated terrains;

Built to endure a wide range of ambient temperatures, from a frigid -40°C to a warm +60°C, accommodating diverse climatic conditions;

Seamlessly adapts to power supply frequencies ranging from a steady 48Hz to a vigorous 62Hz, providing flexibility across various systems;

Maintains optimal power frequency voltage between terminals, ensuring consistent performance for extended use, safeguarding your systems efficiently.

Designed to withstand seismic activities with intensities up to 8 degrees, offering resilience in earthquake-prone areas.

Structured to resist wind forces with speeds soaring up to 35 meters per second, perfect for robust outdoor applications;

Note:

Should your conditions exceed these outlined operational parameters, don't hesitate to engage with our experts for bespoke solutions tailored to your unique needs.

Main technical parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Crafted with a sturdy Polymeric construction for enhanced durability and longevity;

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Features a Porcelain Series Gap specification, providing a classic touch with modern reliability.

Installation

(1) Prior to installation, verify the nameplate to ensure that the arrester’s rated system voltage matches the system voltage at the point of installation for optimal performance;

(2) Offers versatile installation choices with suspension or vertical installation options. Note: Avoid using the arrester as a load-bearing insulator in vertical setups;

(3) Optimize the lead wire length to uphold protection efficiency and prevent unnecessary stress on equipment, ensuring smooth operation.

Test

  • To fortify operational dependability, preventive tests are suggested every 4-5 years focusing primarily on measuring U1mA at both terminals of the DC 1mA arrester.
  • Before installation, confirm the U1mA voltage is no less than 97% of the original factory specification and ensure this data is meticulously recorded.
  • During preventive maintenance, ensure that the U1mA voltage remains above 26kV to maintain operational integrity.
  • Note: Minimize harmonic distortion in the DC power supply during tests as suboptimal waveforms can lead to decreased U1mA readings.
  • The newly launched 10kV synthetic insulated zinc oxide arrester for power distribution has undergone rigorous lab testing, proving its reliable performance under outdoor line voltage conditions for 15 months. The outcomes attest to its jacket's superior quality, the arrester's robust structural reliability, and steadfast core stability. Supported by annual performance insights from 2,000 units, this product assures top-tier protection, minimizes failure rates, and offers maintenance-free functionality throughout its operational lifespan.Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs
Certifications

Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs

Company Profile

Tailored Voltage Surge Arrester Solutions for Customizable Protection Needs

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier