Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of US$ 140/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
  • Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
  • Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
  • Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
  • Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
  • Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
Product Description

Introducing the (H)GWBEB type outdoor high-voltage isolation switch, a pinnacle of engineering designed specifically for 10(12, 15, 24)kV power transmission and distribution lines. This state-of-the-art isolation disconnect switch efficiently opens and closes single-phase or three-phase circuits without load, yet under voltage, ensuring seamless and reliable power management.

Crafted for excellence, this switch is tailored for single-phase use within three-phase systems, boasting a simple yet robust structure, unmatched cost-effectiveness, and user-friendly operation. Available in a range of rated currents: 200, 400, 600, 800, 1000, and 1250 amps, these switches are composed of a sturdy base, high-quality post insulators, precise conductive elements, and a sophisticated mechanical section. The innovative gate knife structure, equipped with dual conductive blades and external compression springs, allows for precise circuit control. Adjust the spring height to ensure perfect contact pressure. Operation is a breeze with an insulated hook stick, complemented by a secure self-locking device.

Working Environment:

Designed for altitudes not exceeding 1000 meters;

Engineered to function optimally within ambient temperatures from a chilly -30°C to a sweltering +40°C;

Built to withstand outdoor wind speeds of up to 35 meters per second;

Constructed for seismic stability, withstanding intensities up to 8 degrees; ideal for areas without frequent severe vibrations.

The installation site should remain free from gases, chemical deposits, salt mist, dust, dirt, or any explosive or corrosive substances that could compromise the switch's superior insulation and conductivity.

Note:

WHEN THE ABOVE NORMAL USE CONDITIONS ARE EXCEEDED, USERS ARE ENCOURAGED TO ENGAGE IN DIALOGUE WITH THE COMPANY FOR CUSTOMIZED SOLUTIONS.

Installation, Use and Adjustment

Pre-installation work

  1. Thoroughly remove dust and dirt from all components, ensuring a clean surface for the insulating porcelain bottle.
  2. Meticulously scrub the wiring surface of the ground screw to ensure optimal connectivity.
  3. Apply a protective layer of industrial Vaseline on rotating parts and contact points to enhance durability.
  4. Inspect and adjust the contact surface and compression spring height to match specifications in Table II, ensuring optimal contact pressure.
  5. This switch is expertly designed for hoisting applications and seamlessly integrates with transformers along the line, enhancing operational efficiency.
  6. The switch boasts a rated current capacity of 200-400 amperes, utilizing three mounting holes, while the 600-1000A range also requires three mounting points for secure installation.

Commit to annual inspections of the switch, focusing on these critical components:
Diligently clear any dirt from conductive parts, contact surfaces, and the insulating porcelain bottle to maintain performance.

Inspect all components for wear or damage, with particular attention to the integrity of the insulating porcelain bottle for any signs of fractures or damage.

Ensure the conductive part's contact surface maintains excellent condition, free from any defects.


Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units

Detailed Photos

Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units


Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units

Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units
Premium Outdoor Isolation Switch High Voltage Load Break Disconnector Units

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Premium Outdoor Isolation Switch High Voltage Load Break Disconnector UnitsPremium Outdoor Isolation Switch High Voltage Load Break Disconnector Units

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier