(H) RW(F) series outdoor high voltage AC drop fuse stands as a pinnacle in the engineering of contemporary electrical systems. Expertly crafted for the rigorous demands of outdoor overhead distribution networks, this innovative fuse operates at a frequency of 50Hz and deftly handles an impressive voltage range of 10kV (12/15/35/40.5). As a vital guardian of electrical integrity, it vigilantly protects circuits and equipment from the dangers of overloads and short-circuits. In normal conditions, its tensioned design ensures secure connectivity within the power line. However, in the event of a fault, the fuse's intelligent mechanism swiftly responds, allowing the fault current to blow the fuse and trigger the release of the movable joint. This rapid action ensures the fuse tube drops instantly, severing the circuit and delivering essential protection for maintenance operations. Enhanced by an elastic contact and a specialized arc extinguishing cover, this load-type fuse excels in both opening and closing the load current, maintaining system safety and reliability.
Our fuse is a paragon of precision, meticulously crafted to the highest technical standards. It adheres to GB / T 15166.3 - 2008 for high voltage AC fuses, Part 3: injection fuses, as well as DL / T 640 - 1997 for outdoor AC high voltage drop-tested fuses. These rigorous standards ensure our product delivers unmatched performance and dependability under the most exacting technical conditions.
Working Environment:
This product is engineered for resilience across a broad ambient temperature spectrum, from a frigid -40°C to a balmy +40°C, guaranteeing steadfast performance in varied climates.
Exhibiting remarkable durability, this fuse accommodates environments with relative humidity where the daily average remains under 95% and the monthly average under 90%, enabling it to thrive in high humidity conditions.
Engineered for altitudes up to 3000 meters, this fuse is versatile enough to perform efficiently across diverse geographical landscapes.
Designed to face the elements, this fuse maintains its stability and functionality even in outdoor wind speeds up to 34 meters per second, ensuring reliable performance in windy situations.
For unparalleled safety and performance, the installation site must be free from fire, explosion hazards, and corrosive chemical gases, with ample ventilation to ensure optimal operation.
Note: Should the usual operating conditions be surpassed, we encourage users to engage in dialogue with our company for tailored solutions to maintain safety and efficiency.
Technical parameters
Note: We are proud to offer customizable solutions, tailoring our products to meet the exacting specifications of our customers.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |