Customization: | Available |
---|---|
Type: | High-voltage |
Structure: | Three-column Disconnector |
Still deciding? Get samples of US$ 800/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introducing the ZW32-12 outdoor high voltage vacuum circuit breaker, a masterpiece in outdoor distribution switchgear engineering, commonly referred to as the 'circuit breaker.' This exceptional device is meticulously designed to function seamlessly at a rated voltage of 12kV, with a robust and reliable three-phase AC of 50Hz. Expertly crafted to manage the interruption and connection of load current, overload current, and short circuit current within power grids, this circuit breaker excels with its advanced overload and short circuit protection. It elegantly meets control and measurement requirements and is equipped with cutting-edge remote control and monitoring capabilities. Its versatility and reliability make it a preferred choice for substations, industrial applications, and mining enterprise distribution systems, offering unmatched control and operational efficiency, even in environments demanding frequent operations.
Structural features:
Crafted with precision and expertise, this circuit breaker proudly exhibits a three-phase pillar dry design, elevating performance and reliability;
Ingeniously engineered with a fully enclosed structure, it provides unrivaled sealing, superior moisture resistance, and exceptional anti-condensation properties, establishing it as the ideal solution for high-temperature and humid regions;
Incorporates cutting-edge vacuum arc extinguishing technology, delivering remarkable insulation reliability and ensuring optimal performance under challenging conditions;
Offers impeccable opening and closing performance, guaranteeing user safety with no risk of combustion or explosion;
Compact and lightweight, this unit demands no maintenance and promises an extraordinary lifespan, enhancing efficiency and value;
Boasts versatile operation modes, including manual, electric, or remote control, to suit your specific needs;
The operating mechanism is meticulously sealed at the base of the switch box, providing robust protection against environmental corrosion, ensuring durability and longevity;
Features an innovative, straightforward design with a restless mechanism that ensures outstanding dynamic performance, a compact form, and an extraordinary service life reaching up to 10,000 cycles.
Main technical parameters:
No |
Name |
Unit |
Data |
|||
1 |
Rated voltage |
kV |
12 |
|||
2 |
Rated current |
A |
630 |
1250 |
||
3 |
Rated frequency |
Hz |
50 |
|||
4 |
Rated insulation level |
1min power frequency withstand voltage |
Dry test |
/ |
42/48(fracture) |
|
Wet test |
34 |
|||||
Secondary circuit to ground |
2 |
|||||
Lightning impulse withstand voltage (peak value) |
75/85(fracture) |
|||||
5 |
Rated short circuit making current (peak value) |
kA |
50 |
63 |
||
6 |
Rated short time withstand current |
kA |
20 |
25 |
||
7 |
Rated peak withstand current |
kA |
50 |
63 |
||
8 |
Breaking times of rated short circuit breaking current |
Times |
30 |
|||
9 |
Rated short circuit duration |
s |
4 |
|||
10 |
Rated operating voltage and rated voltage of auxiliary circuit |
V |
DC220,AC220 ,AC/DC220 |
|||
11 |
Rated operation sequence |
/ |
Off-0.3s-on-off-180s-on-off |
|||
12 |
Rated current of over current trip |
A |
5 |
|||
13 |
Mechanical life |
second |
10000 |
|||
14 |
Allowable wear accumulative thickness of moving and static contacts |
mm |
3 |
|||
15 |
Rated current of over current release |
A |
5 |
|||
16 |
Current ratio of current transformer |
/ |
200/5 400/5 600/5 |
|||
17 |
Contact opening distance |
mm |
9±1 |
|||
18 |
Contact overtravel |
mm |
2±0.5 |
|||
19 |
Average opening speed |
m/s |
1.2±0.3 |
|||
20 |
Average closing speed |
m/s |
0.6±0.2 |
|||
21 |
Opening time |
ms |
≤40 |
|||
22 |
Closing time |
ms |
20~45 |
|||
23 |
Closing bounce time |
ms |
≤2 |
|||
24 |
Asynchrony of three phase closing and opening |
mm |
≤2 |
|||
25 |
Three phase circuit resistance |
μΩ |
≤80 Band isolation≤120 |