Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse is a marvel of contemporary electrical engineering, meticulously crafted for cutting-edge electrical systems. This fuse is a pinnacle of protection for outdoor overhead distribution networks, operating seamlessly at a frequency of 50Hz across an impressive voltage spectrum of 10kV (12/15/35/40.5). It is a crucial asset in the defense against electrical overloads and short circuits, providing unparalleled safety to circuits and electrical apparatus. In its default position, it remains taut and securely anchored within the power line, ensuring unfaltering connectivity. In the event of a fault, its ingenious design swiftly responds, enabling the fault current to rupture the fuse. This triggers the activation of the movable joint, causing the fuse tube to drop with precision and speed, effectively severing the circuit. This prompt action delivers indispensable safety assurance during maintenance operations. Featuring an elastic contact and a sophisticated arc extinguishing cover, this load type fuse excels in the efficient control of load currents within power systems.
Crafted with precision, our fuse adheres to stringent technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses, Part 3: injection fuses, and DL / T 640 - 1997 for outdoor AC high voltage drop tested fuses. Compliance with these standards ensures the pinnacle of performance and dependability under defined technical conditions, offering you peace of mind.
Working Environment:
This product is expertly engineered to operate within a broad ambient temperature span from a frigid -40°C to a balmy +40°C, guaranteeing resilient performance across diverse climatic conditions.
With an impressive relative humidity tolerance, where the daily average does not exceed 95%, and the monthly average remains below 90%, this fuse is meticulously constructed to endure in high humidity settings.
Designed for altitudes not exceeding 3000 meters, it adeptly accommodates a variety of geographical landscapes, proving its versatility in different locales.
Fortified to withstand outdoor wind speeds up to a robust 34 meters per second, this fuse remains steadfast and fully operational in windy environments, ensuring unyielding functionality.
The installation site must be devoid of fire, explosion risks, and chemical corrosive gases, and must be well-ventilated, ensuring optimal performance and uncompromised safety.
Note: Should circumstances surpass the prescribed normal use conditions, we encourage users to engage with our company for tailored solutions that ensure ongoing safety and operational efficiency.
Technical parameters
Note: We proudly offer bespoke solutions, crafting products with precision to align with specific user requirements, ensuring satisfaction and tailored excellence.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |