Outdoor Isolator Switch with High Load Break Disconnector Specifications

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of US$ 140/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Outdoor Isolator Switch with High Load Break Disconnector Specifications
  • Outdoor Isolator Switch with High Load Break Disconnector Specifications
  • Outdoor Isolator Switch with High Load Break Disconnector Specifications
  • Outdoor Isolator Switch with High Load Break Disconnector Specifications
  • Outdoor Isolator Switch with High Load Break Disconnector Specifications
  • Outdoor Isolator Switch with High Load Break Disconnector Specifications
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Outdoor Isolator Switch with High Load Break Disconnector Specifications
Product Description

The (H)GWBEB type Outdoor High-Voltage Isolation Switch, also affectionately known as an isolation disconnect switch, is masterfully engineered for seamless operation on 10(12, 15, 24)kV high voltage power transmission and distribution lines. This sophisticated equipment expertly opens and closes single-phase or three-phase circuits, handling the intricacy of voltage presence, albeit without load.

Tailored for single-phase applications within three-phase line systems, this switch is renowned for its efficient yet straightforward design, cost-effectiveness, and unparalleled ease of operation. It offers a range of rated currents: 200, 400, 600, 800, 1000, and 1250 amps, catering to various needs. Each switch comprises a robust base, dependable post insulators, conductive components, and a precision mechanical section. Utilizing an innovative gate knife structure, the switch enables precise opening and closing of circuits. Each phase's gate knife features twin conductive blades, complemented by external compression springs on both sides, allowing easy adjustment of spring height for optimal contact pressure. With an insulated hook stick facilitating the open-close mechanism, the switch also boasts a self-locking device for added security.

Working Environment:

The switch operates optimally at altitudes not exceeding 1000 meters;

Temperature resilience ranges from a maximum of +40°C to a minimum of -30°C.

Capable of withstanding outdoor wind speeds up to 35 meters per second;

Designed to endure seismic intensities not exceeding 8 degrees, it is crucial that the installation site remains free from frequent severe vibrations.

Installation sites must be clear of gases, chemical deposits, salt mist, dust, dirt, or any explosive or corrosive elements detrimental to the switch's insulation and conductivity.

Note:

SHOULD THE ABOVE NORMAL CONDITIONS BE SURPASSED, USERS ARE ENCOURAGED TO ENTER INTO NEGOTIATIONS WITH THE COMPANY TO ADDRESS THEIR NEEDS.

Installation, Use and Adjustment

Pre-installation work

  1. Begin by eradicating any dust and dirt from the switch components, followed by a meticulous cleaning of the insulating porcelain bottle's surface.
  2. Thoroughly scrub the wiring surface of the grounding screw to ensure optimal contact.
  3. Apply a protective layer of industrial Vaseline to rotating parts and contact areas to maintain operational integrity.
  4. Inspect the contact surfaces meticulously and adjust the compression spring height to meet the specifications detailed in Table II, ensuring proper contact pressure.
  5. This switch is exclusively designed for hoisting use and is intended for integration with transformers on the line.
  6. The rated current for this switch varies between 200-400 ampere hours, typically involving the use of three mounting holes, while the 600-1000A range also employs three mounting holes.

Conduct an annual inspection of the following switch components to guarantee performance:
Regularly cleanse dirt from conductive parts, contact surfaces, and the insulating porcelain bottle's exterior to maintain efficiency.

Carefully examine all parts for any signs of damage, with particular attention to the insulating porcelain bottle to check for cracks or other impairments.

Assess the quality of the contact surfaces of the conductive components to ensure optimal performance.


Outdoor Isolator Switch with High Load Break Disconnector Specifications

Detailed Photos

Outdoor Isolator Switch with High Load Break Disconnector Specifications
Outdoor Isolator Switch with High Load Break Disconnector Specifications
Outdoor Isolator Switch with High Load Break Disconnector Specifications
Outdoor Isolator Switch with High Load Break Disconnector Specifications


Outdoor Isolator Switch with High Load Break Disconnector Specifications
Outdoor Isolator Switch with High Load Break Disconnector Specifications

Outdoor Isolator Switch with High Load Break Disconnector Specifications
Outdoor Isolator Switch with High Load Break Disconnector Specifications
Outdoor Isolator Switch with High Load Break Disconnector Specifications
Outdoor Isolator Switch with High Load Break Disconnector Specifications
Outdoor Isolator Switch with High Load Break Disconnector Specifications
Outdoor Isolator Switch with High Load Break Disconnector Specifications
Outdoor Isolator Switch with High Load Break Disconnector Specifications
Outdoor Isolator Switch with High Load Break Disconnector Specifications
Outdoor Isolator Switch with High Load Break Disconnector Specifications
Outdoor Isolator Switch with High Load Break Disconnector Specifications
Outdoor Isolator Switch with High Load Break Disconnector Specifications
Outdoor Isolator Switch with High Load Break Disconnector Specifications

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Outdoor Isolator Switch with High Load Break Disconnector SpecificationsOutdoor Isolator Switch with High Load Break Disconnector Specifications

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier