Polymeric Surge Protection with Customizable Features for Maximum Efficiency

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Polymeric Surge Protection with Customizable Features for Maximum Efficiency
  • Polymeric Surge Protection with Customizable Features for Maximum Efficiency
  • Polymeric Surge Protection with Customizable Features for Maximum Efficiency
  • Polymeric Surge Protection with Customizable Features for Maximum Efficiency
  • Polymeric Surge Protection with Customizable Features for Maximum Efficiency
  • Polymeric Surge Protection with Customizable Features for Maximum Efficiency
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd - a groundbreaking marvel of precision and reliability, designed to redefine excellence in lightning protection for 10kV power distribution systems. This cutting-edge device is a testament to innovation, featuring a state-of-the-art zinc oxide valve column coupled with expertly engineered upper and lower electrodes. Each component is flawlessly encapsulated in premium silicone rubber, showcasing extraordinary features that elevate industry standards:

  1. Embrace a revolutionary design that triumphantly resolves the sealing challenges traditionally plaguing arresters. Through the ingenious integration of the core and jacket into a unified, compact structure, this design eliminates any potential cavities that could lead to internal breathing issues, thereby masterfully overcoming the technical barriers related to preventing moisture ingress in internal components.
  2. Exhibiting a robust core with unparalleled capacity to withstand internal overvoltage, this arrester delivers remarkable aging resistance. It guarantees that the device retains its superior performance and provides steadfast protection over extended periods, demonstrating extraordinary resilience and longevity regardless of time or conditions.

With a specially crafted valve plate and optimized core parameters, this device ensures exceptional protection. The expertly designed core is capable of withstanding challenges such as arc grounding, PT resonance, and diverse operational overvoltages, consistently operating with unparalleled reliability under line voltage while enduring 2.5 to 3 times power frequency overvoltage. Its voltage withstand duration surpasses international standards by 1 to 3 orders of magnitude, ensuring unmatched safety and operational longevity, thereby setting a new benchmark for high-performance protection solutions.
Polymeric Surge Protection with Customizable Features for Maximum Efficiency

Detailed Photos

Polymeric Surge Protection with Customizable Features for Maximum Efficiency

Polymeric Surge Protection with Customizable Features for Maximum Efficiency
Polymeric Surge Protection with Customizable Features for Maximum Efficiency
Polymeric Surge Protection with Customizable Features for Maximum Efficiency
Polymeric Surge Protection with Customizable Features for Maximum Efficiency
Polymeric Surge Protection with Customizable Features for Maximum Efficiency
Polymeric Surge Protection with Customizable Features for Maximum Efficiency

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Crafted for unparalleled performance, this surge arrester excels in all settings, whether nestled indoors or braving the elements outdoors.

Operates with unwavering confidence at astonishing altitudes of up to 3000 meters, pushing the boundaries of possibility.

Expertly engineered to function in temperatures ranging from a bone-chilling -40°C to a balmy +60°C, this device thrives in diverse climates.

Designed for seamless synergy with power supply frequencies from a steady 48Hz to a dynamic 62Hz, ensuring optimal compatibility.

Ensures that the power frequency voltage applied between the terminals remains within the perfect range for long-term, sustainable operation.

Built to endure seismic activities with intensity levels up to 8 degrees, offering remarkable stability and security.

Withstands fierce wind speeds reaching up to 35 meters per second, ensuring unwavering reliability against nature's forces.

Note:

For conditions surpassing these standard parameters, our team is poised to craft bespoke solutions tailored precisely to your requirements.

Main technical parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Constructed with durable Polymeric materials, this product's resilience is second to none.

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Incorporates a Porcelain Series Gap specification to enhance sophistication and functionality.

Installation

(1) Prior to installation, check the nameplate to ensure the arrester's system rated voltage aligns with the installation point's system voltage.

(2) Offers versatile installation methods, including suspension and vertical mounting. When vertical, ensure the arrester isn't used as a load-bearing insulator.

(3) Optimize lead wire length to maximize protection efficiency and minimize unnecessary equipment stress.

Test

  • To bolster operational reliability, conduct preventive tests every 4-5 years, focusing on measuring U1mA at both terminals of the DC 1mA arrester.
  • Before installation, confirm the U1mA voltage is at least 97% of the factory value, meticulously recording this for future reference.
  • During preventive maintenance, ensure that the U1mA voltage consistently exceeds 26kV.
  • Note: Reduce harmonic components in the DC power supply during tests to avoid low U1mA readings due to poor waveform quality.
  • The newly launched 10kV synthetic insulated zinc oxide arrester for power distribution has excelled in rigorous lab testing. It performed reliably under outdoor line voltage for 15 months, demonstrating the jacket's superior quality, robust arrester structure, and unmatched core stability. Supported by annual performance data from 2,000 units, it offers unparalleled protection, significantly reduced failure rates, and maintenance-free operation throughout its lifecycle.Polymeric Surge Protection with Customizable Features for Maximum Efficiency
Certifications

Polymeric Surge Protection with Customizable Features for Maximum Efficiency

Company Profile

Polymeric Surge Protection with Customizable Features for Maximum Efficiency

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier