Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
  • Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
  • Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
  • Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
  • Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
  • Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
Product Description

(H)GWBEB type outdoor high-voltage isolation switch, an impressive and indispensable component also known as an isolation disconnect switch, has been meticulously engineered for application on 10(12, 15, 24)kV high voltage power transmission and distribution lines. Its purpose is to effectively open and close single-phase or three-phase circuits without load, even with voltage present, enhancing your power system's flexibility.

Crafted for single-phase applications within three-phase line systems, this switch boasts an ingeniously simple structure, making it not only cost-effective but also user-friendly. With an array of available rated currents—200, 400, 600, 800, 1000, and 1250 amps—this switch is versatile and adaptable. The robust build includes a reliable base, post insulators, conductive parts, and a mechanical section. The circuit is opened and closed using a sophisticated gate knife structure, where each phase's gate knife comprises two conductive blades, secured with external compression springs on either side. By adjusting the spring height, you can achieve the optimal contact pressure essential for the switch’s gate knife. It operates using an insulated hook stick for seamless opening and closing actions, complemented by a self-locking device, ensuring steadfast performance.

Working Environment:

Altitude not exceeding 1000 meters; ensuring optimal performance and reliability.

Ambient temperature: maintaining a maximum of +40°C and a minimum of -30°C; adaptable to a wide range of climates.

Outdoor wind speed not exceeding 35 meters/second; designed to withstand robust weather conditions.

Seismic intensity not exceeding 8 degrees; the installation site should remain free from frequent severe vibrations, safeguarding the switch's integrity and reliability.

The installation site should be free from harmful gases, chemical deposits, salt mist, dust, dirt, or other explosive or corrosive mediums that could compromise the switch's insulation and conductivity. This ensures long-term durability and efficiency.

Note:

WHEN THE ABOVE NORMAL USE CONDITIONS ARE EXCEEDED, THE USER CAN NEGOTIATE WITH THE COMPANY for tailored solutions to meet unique requirements.

Installation, Use and Adjustment

Pre-installation work

  1. Carefully remove any dust and dirt from the parts, and meticulously wipe the surface of the insulating porcelain bottle to ensure optimal performance.
  2. Thoroughly scrub the wiring surface of the ground screw for perfect connectivity.
  3. Apply a protective layer of industrial Vaseline to the rotating parts and contact areas, ensuring smooth operation and longevity.
  4. Inspect the contact surface and adjust the height of the compression spring so that the contact pressure aligns perfectly with Table II standards, ensuring superior performance.
  5. This switch is exclusively designed for hoisting use and serves as a crucial component in conjunction with the transformer on the line for enhanced operational capabilities.
  6. The rated current of this switch spans 200-400 ampere hours, typically using three mounting holes, while the 600-1000A variant also uses three mounting holes, ensuring secure installation and performance.

Conduct an annual inspection of the following switch parts to maintain optimal functionality:
Meticulously remove any dirt from conductive parts, contact surfaces, and the insulating porcelain bottle surface to prevent operational hindrances.

Inspect all parts for potential damage, with a particular focus on the insulating porcelain bottle for any cracks or imperfections.

Verify the condition of the conductive part's contact surface to ensure high efficiency and reliability.


Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch

Detailed Photos

Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch


Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch

Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch
Medium Voltage Load Break Isolator Switch Outdoor Disconnect Switch

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Medium Voltage Load Break Isolator Switch Outdoor Disconnect SwitchMedium Voltage Load Break Isolator Switch Outdoor Disconnect Switch