Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The (H) RW(F) series outdoor high voltage AC drop fuse, subsequently referred to as the 'fuse', is expertly crafted for integration into outdoor overhead distribution systems. Tailored for systems with a rated frequency of 50Hz and a rated voltage of 10kV (scalable to 12/15/35/40.5), this fuse is your frontline defense against circuit overloads and short circuit faults. Seamlessly embedded within the power line, the fuse stands in a state of readiness, with its mechanism securely locked. Upon the detection of a fault, the resultant fault current triggers the fuse to disconnect, releasing the movable joint, swiftly disengaging the fuse tube, and effectively isolating the circuit. This dynamic process ensures paramount safety, safeguarding both line and equipment maintenance. The advanced load-type fuse incorporates an elastic contact and arc extinguishing cover, elevating its functionality to not only protect but also adeptly manage load currents within the power system.
Our fuses meet rigorous technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses, Part 3: injection fuses, and DL / T 640 - 1997 for outdoor AC high voltage drop-tested fuses, along with comprehensive fuse links ordering technical conditions.
Working Environment:
Designed for a versatile range, the ambient temperature must be between -40°C and +40°C.
Optimal operation within relative humidity parameters: daily averages not exceeding 95% and monthly averages not surpassing 90%.
Functionality assured at altitudes up to 3000 meters.
Capable of withstanding outdoor wind speeds of up to 34 meters per second.
Select installation sites devoid of fire, explosion hazards, or chemical corrosive gases, ensuring adequate ventilation.
Note: For conditions beyond these specified norms, users are encouraged to consult with our company for tailored solutions.
Technical parameters
Note: Our company is fully equipped to customize products to meet user-defined specifications.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |