Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, commonly known as the 'fuse', is expertly designed for application in outdoor overhead distribution systems. With its highly efficient performance, this fuse operates at a rated frequency of 50Hz and supports a rated voltage of 10kV, accommodating variations such as 12/15/35/40.5. It serves as a critical protective component for circuits and electrical equipment, especially during overload or short circuit incidents in power systems. Under normal operational conditions, the fuse is elegantly integrated in series within the power line, maintaining a tensioned state with the movable joint securely locked. In the event of a line failure, the resultant fault current initiates the blowing of the fuse, consequently releasing the movable joint. This prompts the swift dropping of the fuse tube, efficiently severing the circuit to provide essential safety protection, thereby facilitating maintenance of the line and equipment. Enhancing the functionality of the ordinary type, the load-type fuse is equipped with an elastic contact and an innovative arc extinguishing cover, adeptly designed to manage the opening and closing of load currents within the power system.
This fuse proudly adheres to esteemed technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses, specifically Part 3 concerning injection fuses. It also meets DL / T 640 - 1997 standards, which pertain to outdoor AC high voltage drop-tested fuses and the technical conditions for ordering fuse links.
Working Environment:
Ambient temperature: -40°C to +40°C;
Relative humidity: daily average not exceeding 95%, with a monthly average not exceeding 90%;
Altitude: not exceeding 3000 meters;
Outdoor wind speed: must not exceed 34 meters per second;
Installation site: should be free from fire, explosion hazards, and chemical corrosive gases, ensuring a well-ventilated environment.
Note: Should the conditions for normal use surpass the specified limits, users are encouraged to negotiate with the company for tailored solutions.
Technical parameters
Note: Our company is dedicated to accommodating user requirements, offering products tailored to specific needs.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |