Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introducing the (H) RW(F) series, a robust outdoor high voltage AC drop fuse engineered for excellence. Specifically designed for outdoor overhead distribution systems with a rated frequency of 50Hz and rated voltage of 10kV (12/15/35/40.5), this innovative fuse serves as a critical protective element. It safeguards circuits and electrical equipment from overloads and short circuits, ensuring optimal safety. In normal conditions, the fuse remains secure in a tensioned state, with its movable joint impeccably locked. Upon a fault, the fault current triggers the fuse to blow, promptly releasing the joint, and dropping the fuse tube to safely interrupt the circuit. Enhanced with elastic contact and an arc extinguishing cover, this load-type fuse excels in opening and closing load currents within power systems, offering superior safety measures for line and equipment maintenance.
The fuse rigorously adheres to esteemed technical standards such as GB / T 15166.3 - 2008, which governs high voltage AC fuses - Part 3: injection fuses, as well as DL / T 640 - 1997, which specifies ordering technical conditions for outdoor AC high voltage drop tested fuses and fuse links.
Working Environment:
Ambient temperature range: an impressive -40°C to +40°C.
Relative Humidity: Designed for areas where the daily average does not exceed 95%, and the monthly average stays below 90%.
Capable of operating at altitudes not exceeding 3000 meters.
Built to withstand outdoor wind speeds of up to 34 meters per second.
Installation site requirements: Must be free from fire, explosive hazards, and corrosive chemical gases, while ensuring excellent ventilation.
Note: Should the standard usage conditions be exceeded, we welcome discussions for customization to meet your unique requirements.
Technical parameters
Note: We are delighted to offer customized solutions to meet your specific needs. Let us know your requirements, and we'll make it happen.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |