Polymeric Zinc Protector with Customizable Features for Reliable Protection

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Polymeric Zinc Protector with Customizable Features for Reliable Protection
  • Polymeric Zinc Protector with Customizable Features for Reliable Protection
  • Polymeric Zinc Protector with Customizable Features for Reliable Protection
  • Polymeric Zinc Protector with Customizable Features for Reliable Protection
  • Polymeric Zinc Protector with Customizable Features for Reliable Protection
  • Polymeric Zinc Protector with Customizable Features for Reliable Protection
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd - a groundbreaking, fully sealed, and exceptionally reliable innovation in lightning protection specifically designed for 10kV power distribution systems. This state-of-the-art device is expertly engineered, featuring a sophisticated zinc oxide valve column and meticulously crafted upper and lower electrodes. Encased within high-quality silicone rubber, it boasts superior characteristics that redefine industry standards:

  1. This pioneering design elegantly resolves the sealing challenges commonly faced with traditional arresters. By seamlessly merging the core and jacket into a single, cohesive unit, it eliminates cavities that could lead to problematic internal breathing issues, thereby skillfully overcoming the technical challenges associated with preventing moisture ingress in internal components.
  2. Featuring a robust core with an impressive capacity to withstand internal overvoltage, this arrester demonstrates exceptional aging resistance. This ensures that the device consistently delivers high-standard performance over time, providing steadfast protection and demonstrating exceptional durability and longevity under varying conditions.

Through the use of a specially designed valve plate combined with optimized core parameters, this device ensures superior protection. The core is expertly engineered to tackle challenges such as arc grounding, PT resonance, and diverse operational overvoltages. It operates with unparalleled reliability under line voltage, while also withstanding 2.5 to 3 times the power frequency overvoltage. Its voltage withstand duration significantly exceeds international benchmarks by an impressive 1 to 3 orders of magnitude, offering unmatched safety and operational longevity, setting a new benchmark for high-performance protection solutions.
Polymeric Zinc Protector with Customizable Features for Reliable Protection

Detailed Photos

Polymeric Zinc Protector with Customizable Features for Reliable Protection

Polymeric Zinc Protector with Customizable Features for Reliable Protection
Polymeric Zinc Protector with Customizable Features for Reliable Protection
Polymeric Zinc Protector with Customizable Features for Reliable Protection
Polymeric Zinc Protector with Customizable Features for Reliable Protection
Polymeric Zinc Protector with Customizable Features for Reliable Protection
Polymeric Zinc Protector with Customizable Features for Reliable Protection

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

This surge arrester is meticulously crafted for flawless performance, whether indoors or outdoors, ensuring dependable protection and optimum functionality.

Efficiently operates at astounding altitudes of up to 3000 meters, providing reliable protection and performance in elevated environments.

Expertly engineered to function seamlessly across a temperature spectrum from a frosty -40°C to a warm +60°C, adapting effortlessly to diverse climate conditions.

Designed to work harmoniously with power supply frequencies from a stable 48Hz to an energetic 62Hz, ensuring adaptability and consistent power flow.

Assures that the power frequency voltage applied between terminals remains within optimal limits for sustainable, long-lasting operation.

Constructed to withstand seismic events with intensities not exceeding 8 degrees, ensuring unwavering stability and durability.

Capable of withstanding robust outdoor wind speeds up to 35 meters per second, delivering unyielding reliability against natural elements.

Note:

For scenarios exceeding standard operational parameters, our dedicated team is poised to provide bespoke solutions tailored specifically to your needs.

Main technical parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Boasting a durable polymeric construction, the product's design significantly enhances resilience and longevity.

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Incorporates a Porcelain Series Gap specification for sophisticated functionality and superior performance.

Installation

(1) Before initiating installation, verify the nameplate to ensure the arrester's system rated voltage aligns with the system voltage at the installation site.

(2) Offers versatile installation options, including suspension and vertical mounting. For vertical setups, ensure the arrester is not used as a load-supporting insulator.

(3) Optimize lead wire length to maximize protection efficiency and minimize undue stress on your equipment.

Test

  • To enhance operational reliability, conduct preventive tests every 4-5 years, focusing on measuring U1mA at both terminals of the DC 1mA arrester.
  • Before installation, verify that the U1mA voltage is at least 97% of the original factory value, meticulously recording this data for future reference.
  • During preventive maintenance, ensure the U1mA voltage remains above 26kV to maintain optimal performance.
  • Note: Reduce harmonic components in the DC power supply during tests to prevent low U1mA readings caused by waveform irregularities.
  • The newly launched 10kV synthetic insulated zinc oxide arrester for power distribution has excelled in rigorous lab tests, consistently operating under outdoor line voltage conditions for 15 months. The results highlight the jacket's superior quality, the arrester's reliable structure, and robust core stability. Supported by annual performance data from 2,000 units, it ensures unmatched protection, significantly reduced failure rates, and maintenance-free operation throughout its lifecycle.Polymeric Zinc Protector with Customizable Features for Reliable Protection
Certifications

Polymeric Zinc Protector with Customizable Features for Reliable Protection

Company Profile

Polymeric Zinc Protector with Customizable Features for Reliable Protection

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier