Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
  • Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
  • Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
  • Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
  • Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
  • Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
Product Description

The (H)GWBEB type outdoor high-voltage isolation switch, also known as an isolation disconnect switch, is expertly engineered for integration into 10(12, 15, 24)kV high voltage power transmission and distribution lines. This remarkable switch is crafted to safely open and close single-phase or three-phase circuits, managing the presence of voltage effortlessly even without load. Its innovative design ensures operational excellence for a variety of high-voltage environments.

Specifically tailored for single-phase applications within three-phase line systems, this switch boasts a simple, yet highly effective structure that underscores its cost-efficiency and user-friendliness. The impressive range of rated currents available includes 200, 400, 600, 800, 1000, and 1250 amps, accommodating diverse electrical needs. The switch's construction is robust, featuring a reliable base, post insulators, conductive components, and a mechanical section. The gate knife structure facilitates precise circuit operations, with each phase's gate knife composed of dual conductive blades, enhanced by external compression springs. These springs are adjustable for optimal contact pressure, ensuring seamless gate knife performance. The operation of the switch is conveniently managed through an insulated hook stick, providing ease in opening and closing actions, all while incorporating a self-locking device for added safety and security.

Working Environment:

This switch is designed to function optimally at altitudes not exceeding 1000 meters;

It maintains efficiency with an ambient temperature range where the maximum does not rise above +40°C, and the minimum does not fall below -30°C;

Adaptable to outdoor conditions, it withstands wind speeds not exceeding 35 meters per second;

It is engineered to operate smoothly in areas where seismic intensity does not exceed 8 degrees, ensuring stability even amidst occasional vibrations.

The installation site must be free from gases, chemical deposits, salt mist, dust, dirt, or any explosive or corrosive mediums that might significantly impair the switch's insulation and conductivity. Such conditions are crucial for maintaining optimal performance and longevity.

Note:

IF THE AFOREMENTIONED STANDARD CONDITIONS ARE EXCEEDED, USERS ARE ENCOURAGED TO DISCUSS AND CONSULT SPECIFIC REQUIREMENTS WITH THE COMPANY FOR CUSTOM SOLUTIONS.

Installation, Use and Adjustment

Pre-installation work

  1. Begin by meticulously removing dust and dirt from all components, taking special care to delicately clean the surface of the insulating porcelain bottle.
  2. Ensure a clean and efficient grounding by scrubbing the wiring surface of the ground screw.
  3. Apply a protective layer of industrial Vaseline to all rotating parts and contact areas, enhancing their longevity and operational fluidity.
  4. Verify the integrity of the contact surface and adjust the compression spring's height to meet the contact pressure specifications outlined in Table II. This ensures optimal functionality.
  5. This switch is specifically designed for hoisting applications and is intended for use in conjunction with transformers on the line, enhancing its versatility and applicability.
  6. The switch is rated for 200-400 ampere hours, typically necessitating the use of only three mounting holes. For 600-1000A applications, three mounting holes are consistently utilized, ensuring secure installation.

Conduct an annual inspection to ensure the switch's optimal performance by checking the following components:
Thoroughly clean any accumulated dirt from the conductive parts, contact surfaces, and the insulating porcelain bottles to maintain efficiency.

Inspect all components for potential damage, paying particular attention to the insulating porcelain bottles for any signs of damage or cracking.

Ensure that the contact surface of each conductive part remains in excellent condition, guaranteeing reliable operation.


Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities

Detailed Photos

Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities


Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities

Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities
Outdoor High Voltage Isolation Switch with Custom Load Break Capabilities

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35