Customizable High Voltage Surge Arrester for Enhanced Protection Solutions

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of US$ 35/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Customizable High Voltage Surge Arrester for Enhanced Protection Solutions
  • Customizable High Voltage Surge Arrester for Enhanced Protection Solutions
  • Customizable High Voltage Surge Arrester for Enhanced Protection Solutions
  • Customizable High Voltage Surge Arrester for Enhanced Protection Solutions
  • Customizable High Voltage Surge Arrester for Enhanced Protection Solutions
  • Customizable High Voltage Surge Arrester for Enhanced Protection Solutions
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Packaging & Delivery

Package Size
28.00cm * 15.00cm * 30.00cm
Package Gross Weight
2.000kg

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd—a groundbreaking, fully sealed lightning protection marvel designed specifically for 10kV power distribution systems. This state-of-the-art device showcases a zinc oxide valve column, expertly integrated with upper and lower electrodes, all expertly enveloped in silicone rubber. This sophisticated construction delivers unmatched performance and reliability, making it the ideal choice for safeguarding your electrical infrastructure.

  1. This pioneering design skillfully tackles and resolves the sealing challenges that have long plagued traditional arresters. By seamlessly merging the core and jacket into one cohesive unit, it eliminates any cavities that could cause internal breathing issues, thereby deftly overcoming the technical challenges associated with preventing moisture ingress into internal components.
  2. Featuring a sturdy core with an impressive ability to withstand internal overvoltage, this arrester exhibits outstanding aging resistance, ensuring consistent performance and steadfast protection year after year. Its durability and long-term efficiency make it a valuable asset for any power distribution system.

Incorporating a specially designed valve plate alongside optimized core parameters, this device ensures that the core effectively handles challenges such as arc grounding, PT resonance, and various operational overvoltages. It operates with exceptional reliability under line voltage while enduring 2.5 to 3 times power frequency overvoltage. Its voltage withstand duration exceeds international standards by 1 to 3 orders of magnitude, guaranteeing superior safety and exceptional operational longevity.
Customizable High Voltage Surge Arrester for Enhanced Protection Solutions

Detailed Photos

Customizable High Voltage Surge Arrester for Enhanced Protection Solutions

Customizable High Voltage Surge Arrester for Enhanced Protection Solutions
Customizable High Voltage Surge Arrester for Enhanced Protection Solutions
Customizable High Voltage Surge Arrester for Enhanced Protection Solutions
Customizable High Voltage Surge Arrester for Enhanced Protection Solutions
Customizable High Voltage Surge Arrester for Enhanced Protection Solutions
Customizable High Voltage Surge Arrester for Enhanced Protection Solutions

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Expertly engineered for flawless operation indoors and outdoors, ensuring your systems are safeguarded in any environment.

Excellently performs at breath-taking altitudes reaching up to 3000m, catering to diverse geographical needs.

Designed to endure a wide range of temperatures, from a freezing -40C to a warm +60C, offering unparalleled adaptability.

Seamlessly integrates with power supply frequencies from a steady 48Hz to a vibrant 62Hz, enhancing versatility.

Guarantees that power frequency voltage between terminals remains within ideal parameters, promoting consistent and reliable operation over time.

Built to withstand seismic forces of up to 8 degrees, providing peace of mind in tremor-prone areas.

Skillfully crafted to resist strong outdoor winds up to 35 meters/second, ensuring durability and stability.

Note:

If you encounter conditions beyond these typical operational settings, our team is ready to discuss and craft personalized solutions to meet your specific needs.

Main technical parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Distinguished by a strong Polymeric construction, offering superior durability.

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Features the Porcelain Series Gap specification for enhanced reliability.

Installation

(1) Before installation, confirm the nameplate to ensure the arrester’s system rated voltage matches the system voltage at the installation site, ensuring optimal safety and performance.

(2) Provides installation flexibility with suspension or vertical options. For vertical installations, avoid using the arrester as a load-bearing insulator to preserve its integrity.

(3) Optimize lead wire length to ensure maximum protection efficiency and reduce stress on the equipment, safeguarding against potential issues.

Test

  • lTo boost operational dependability, conduct preventive tests every 4-5 years. Focus on measuring U1mA at both terminals of the DC 1mA arrester for accurate assessment.
  • lPrior to installation, confirm the U1mA voltage is at least 97% of the factory value and meticulously document this data for reference.
  • lDuring preventive maintenance, ensure U1mA voltage remains above 26kV to maintain optimal functionality.
  • lNote: It's crucial to minimize harmonic components in the DC power supply during tests, as poor waveforms can lead to inaccurately low U1mA readings.
  • lOur newly launched 10kV synthetic insulated zinc oxide arrester for power distribution has undergone extensive laboratory testing, demonstrating reliable performance under outdoor line voltage for 15 months. The results verified: superior jacket quality, dependable arrester construction, and strong core stability. Supported by yearly performance data from 2,000 units, this product ensures top-notch protection, lowers failure rates, and offers maintenance-free operation throughout its life cycle.Customizable High Voltage Surge Arrester for Enhanced Protection Solutions
Certifications

Customizable High Voltage Surge Arrester for Enhanced Protection Solutions

Company Profile

Customizable High Voltage Surge Arrester for Enhanced Protection Solutions

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier