Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) Series Outdoor High Voltage AC Drop Fuse (hereinafter referred to as "fuse") is a top-notch solution designed for outdoor overhead distribution systems with a robust rated frequency of 50Hz and a versatile rated voltage of 10kV (12/15/35/40.5). This extraordinary fuse serves as an indispensable protective mechanism for circuits or electrical equipment, safeguarding them in the event of an overload or short circuit fault within a power system. During normal operation, this fuse is securely connected in series along power lines, ensuring a state of tension while its movable joint is locked, providing unwavering safety. In the unfortunate occurrence of a line failure, the fault current astonishingly causes the fuse to blow, thereby releasing the movable joint. Consequently, the fuse tube swiftly drops, effectively cutting off the circuit, and offering unparalleled safety protection for line and equipment maintenance. Our advanced load type fuse is enhanced with an elastic contact and arc extinguishing cover, distinguishing it from the ordinary type. This innovative feature provides exceptional capability to open and close the load current within the power system.
Standards Compliance: The fuse is meticulously crafted to adhere to rigorous technical standards, including GB / T 15166.3 - 2008 High Voltage AC Fuses - Part 3: Injection Fuses, DL / T 640 - 1997 Outdoor AC High Voltage Drop Tested Fuses, and Fuse Links Ordering Technical Conditions. Our adherence to these standards ensures impeccable reliability and top-tier performance.
Working Environment: Meticulously designed to perform optimally in diverse conditions.
Ambient Temperature: Designed to function seamlessly in harsh climates from -40°C to +40°C.
Relative Humidity: Engineered to endure with a daily average not exceeding 95% and a monthly average not exceeding 90%.
Altitude Capability: Reliable performance at altitudes not exceeding 3000 meters.
Wind Speed Resistance: Unwavering efficiency in outdoor wind speeds up to 34 meters/second.
Installation Site: Suitable for locations free from fire, explosion hazards, and chemical corrosive gases, ensuring proper ventilation and safety.
Note: If the above standard usage conditions are surpassed, we welcome users to engage in negotiations with our company to explore customized solutions.
Technical Parameters: A meticulous enumeration of technical specifications that highlight our product's capabilities.
Note: Our company is dedicated to accommodating user requirements by offering customized product solutions.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |