Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse is a state-of-the-art protective solution, expertly crafted for outdoor overhead distribution systems featuring a rated frequency of 50Hz and a formidable rated voltage range of 10kV to 40.5kV. This fuse stands as a vigilant guardian against overloads and short circuit faults within power systems, serving as an indispensable protective component for circuits and electrical equipment. In normal operation, the fuse integrates seamlessly into the power line, maintaining a tensioned and locked position. Upon encountering a fault, the surge of fault current triggers the fuse to blow, releasing the movable joint and swiftly disconnecting the fuse tube, thereby ensuring the circuit is effectively interrupted. This sophisticated mechanism provides robust safety protection, facilitating maintenance and safeguarding the integrity of lines and equipment. Enhanced with elastic contacts and an arc extinguishing cover, the load type fuse excels in opening and closing load currents within the power system, setting a standard in operational excellence.
This fuse aligns with the highest technical standards, including GB / T 15166.3 - 2008 high voltage AC fuses - Part 3: injection fuses, and DL / T 640 - 1997 outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions, ensuring unparalleled quality and reliability.
Working Environment:
Ambient temperature: Ranging from a brisk -40°C to a warm +40°C;
Relative humidity: Maintained at a daily average not exceeding 95%, with a monthly average capped at 90%;
Operational altitude: Not surpassing a towering 3000 meters;
Outdoor wind velocity: A maximum of 34 meters per second, ensuring sturdy performance;
Installation site: Must be free from fire, explosion hazards, corrosive chemicals, and should feature excellent ventilation.
Note: Any conditions extending beyond these specified parameters may be negotiated with Beierbian Group Co., Ltd for customized solutions.
Technical parameters
Note: Beierbian Group Co., Ltd is equipped to tailor products to meet specific user requirements, ensuring a bespoke experience.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |