Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements
  • Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements
  • Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements
  • Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements
  • Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements
  • Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd - a groundbreaking solution in lightning protection for 10kV power distribution systems. This fully sealed and remarkably dependable device is a testament to advanced engineering. Crafted with precision, it features a zinc oxide valve column paired with meticulously designed upper and lower electrodes. These components are skillfully encapsulated in high-quality silicone rubber, providing exceptional performance characteristics:

  1. This cutting-edge design adeptly resolves the sealing issues that have long plagued traditional arresters. By ingeniously merging the core and jacket into a single, cohesive unit, it effectively eliminates potential cavities that could lead to internal breathing complications. This innovative approach successfully tackles the technical challenges of moisture ingress prevention within the arrester's internal components.
  2. With a robust core engineered for exceptional resilience, this arrester demonstrates superior aging resistance, ensuring that it maintains consistent performance and steadfast protection over the years. Its formidable ability to endure internal overvoltage sets it apart as a reliable defense against lightning strikes.

Leveraging a specially designed valve plate alongside finely tuned core parameters, this device assures that the core withstands critical challenges such as arc grounding, PT resonance, and a variety of operational overvoltages. It operates with unmatched confidence under line voltage and can endure 2.5 to 3 times the power frequency overvoltage. Its voltage withstand duration far exceeds international standards by 1 to 3 orders of magnitude, delivering extraordinary safety and long-lasting operational reliability.
Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements

Detailed Photos

Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements

Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements
Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements
Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements
Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements
Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements
Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Specially crafted for impeccable performance in both indoor and outdoor settings;

Impressively functions at altitudes soaring up to 3000 meters;

Effortlessly accommodates ambient temperatures from a brisk -40°C to a warm +60°C;

Seamlessly integrates with power supply frequencies ranging from a stable 48Hz to a vibrant 62Hz;

Assures that the power frequency voltage across the terminals stays within ideal ranges for extended service life.

Prepared to endure seismic activity up to an intensity of 8 degrees.

Skillfully designed to withstand robust outdoor winds reaching speeds of up to 35 meters per second;

Note:

If you face conditions beyond these standard operational parameters, our team is ready to discuss bespoke solutions tailored to your needs.

Main technical parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Constructed with a sturdy Polymeric composition

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Features Porcelain Series Gap specification

Installation

(1) Prior to installation, confirm the nameplate to ensure the arrester's system rated voltage corresponds with the installation site's system voltage;

(2) Provides versatility with options for suspension or vertical installation. For vertical installation, ensure the arrester is not used as a load-bearing insulator;

(3) Optimize the lead wire length to preserve protection efficacy and prevent excessive equipment strain.

Test

  • lTo boost operational reliability, conduct preventive tests every 4-5 years, focusing on measuring U1mA at both terminals of the DC 1mA arrester.
  • lBefore installation, confirm that the U1mA voltage is no less than 97% of the original factory value and properly log this data.
  • lDuring preventive maintenance, ensure the U1mA voltage remains above 26kV.
  • lNote: Reduce harmonic components in the DC power supply during tests. Poor waveforms may lead to low U1mA readings.
  • lThe newly launched 10kV synthetic insulated zinc oxide arrester has undergone extensive laboratory tests, validating its consistent performance under outdoor line voltage for 15 months. Test results affirm: superior jacket quality, the arrester's structural dependability, and robust core stability. Combined with annual performance data from 2,000 units, this product assures exceptional protection, decreased failure rates, and maintenance-free operation throughout its service duration.Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements
Certifications

Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements

Company Profile

Premium Polymeric Housed Lightning Arrester for Custom Voltage Requirements

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier