Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) Series Outdoor High Voltage AC Drop Fuse: Engineered for optimal performance in outdoor overhead distribution systems, this sophisticated fuse is specially designed for environments with a rated frequency of 50Hz and a rated voltage of 10kV (12/15/35/40.5). It acts as a vital protective component, safeguarding both circuits and electrical equipment against overloads and short circuit faults. Seamlessly integrated in series within power lines, the fuse maintains a tensioned state with its locked movable joint during normal operation. Upon encountering a fault, the current transforms into a powerful ally, triggering the fuse to blow, unlocking the joint, and swiftly disconnecting the circuit. This elegant mechanism ensures top-tier safety for line and equipment maintenance. Moreover, the advanced load type fuse is enhanced with elastic contact and an arc extinguishing cover, offering exceptional capabilities to open and close load currents within the power system.
Built to stringent standards, the fuse meets all requirements specified in technical standards such as GB / T 15166.3 - 2008 High Voltage AC Fuses - Part 3: Injection Fuses and DL / T 640 - 1997 Outdoor AC High Voltage Drop Tested Fuses and Fuse Links Ordering Technical Conditions.
Working Environment:
Capable of withstanding a broad ambient temperature range from a chilling -40°C to a balmy +40°C;
Ensures reliable performance with a daily relative humidity not surpassing 95% and a monthly average not exceeding 90%;
Adapted for altitudes reaching up to 3000 meters;
Engineered to resist outdoor wind speeds of up to 34 meters per second;
Select installation sites free from fire risks, explosive hazards, and chemical corrosive gases, ensuring a well-ventilated environment.
Note: Should operational conditions exceed the specified limits, users are encouraged to consult with the company for tailored solutions.
Technical Parameters
Note: Our company is committed to versatility and customization, offering products that cater to user-specific requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |