Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) Series Outdoor High Voltage AC Drop Fuse - the epitome of cutting-edge protection! Designed for outdoor overhead distribution systems, this robust 'fuse' is your trusted guardian against overload and short circuit faults in power systems. With a rated frequency of 50Hz and an impressive rated voltage of 10kV (12/15/35/40.5), our product lies at the heart of circuit and electrical equipment safeguarding. Seamlessly integrated into power lines, it becomes a vigilant sentry, ready to act. Upon detecting a fault, it swiftly releases the tensioned fuse tube, interrupting the circuit to ensure total safety for line and equipment maintenance. Enhanced with elastic contact and an arc extinguishing cover, our load type fuse effortlessly manages the opening and closing of load currents in power systems, bringing you unparalleled reliability and peace of mind.
Our fuses are engineered to meet and exceed all relevant technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses - Part 3: injection fuses, and DL / T 640 - 1997, which outlines the requirements for outdoor AC high voltage drop-tested fuses and fuse links ordering technical conditions. Trust in a product that complies with the industry's highest quality benchmarks.
Working Environment:
Designed to perform brilliantly across a wide range of conditions, our fuses thrive in ambient temperatures ranging from a frigid -40°C to a sweltering +40°C;
With resilience against humidity, they work flawlessly even when the daily average reaches up to 95% and the monthly average up to 90%.
Our fuses stand strong in altitudes soaring up to 3000 meters, ensuring dependable performance no matter the elevation.
Engineered to withstand winds of up to 34 meters per second, these fuses are crafted for outdoor durability and resilience.
Ideal for installation in well-ventilated places free from fire, explosion hazards, and corrosive gases, ensuring safe and reliable operation.
Note: Should your application exceed these normal use conditions, we welcome the opportunity to discuss and tailor solutions to your specific needs.
Technical Parameters
Note: At Beierbian Group Co., Ltd, customization is our forte. We stand ready to supply products tailored to meet your unique specifications.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |