Customizable High Bearing Voltage Surge Arrester for Optimal Protection

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of US$ 35/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Customizable High Bearing Voltage Surge Arrester for Optimal Protection
  • Customizable High Bearing Voltage Surge Arrester for Optimal Protection
  • Customizable High Bearing Voltage Surge Arrester for Optimal Protection
  • Customizable High Bearing Voltage Surge Arrester for Optimal Protection
  • Customizable High Bearing Voltage Surge Arrester for Optimal Protection
  • Customizable High Bearing Voltage Surge Arrester for Optimal Protection
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd—a groundbreaking, fully sealed, and exceptionally reliable lightning protection marvel designed specifically for 10kV power distribution systems. This state-of-the-art device is expertly engineered using a zinc oxide valve column, enhanced with upper and lower electrodes, all expertly encapsulated within silicone rubber. This combination offers unmatched characteristics that set a new standard in electrical safety:

  1. This innovative design expertly tackles and resolves the sealing challenges traditionally faced in arresters. By ingeniously merging the core and jacket into a unified, compact structure, it effectively eliminates any cavities that could lead to internal breathing issues. This advanced solution triumphantly overcomes the technical obstacles associated with preventing moisture ingress into internal components, safeguarding the device's integrity.
  2. Featuring a robust core with an extraordinary capacity to withstand internal overvoltage, this arrester demonstrates exceptional aging resistance, ensuring long-lasting performance and steadfast protection year after year, even under the most demanding conditions.

Incorporating a specially crafted valve plate alongside optimized core parameters, this device ensures the core can withstand challenges such as arc grounding, PT resonance, and a variety of operational overvoltages. It operates with unparalleled reliability under line voltage and endures 2.5 to 3 times power frequency overvoltage with ease. Its voltage withstand duration exceeds international standards by 1 to 3 orders of magnitude, guaranteeing supreme safety and operational durability for extended periods.
Customizable High Bearing Voltage Surge Arrester for Optimal Protection

Detailed Photos

Customizable High Bearing Voltage Surge Arrester for Optimal Protection

Customizable High Bearing Voltage Surge Arrester for Optimal Protection
Customizable High Bearing Voltage Surge Arrester for Optimal Protection
Customizable High Bearing Voltage Surge Arrester for Optimal Protection
Customizable High Bearing Voltage Surge Arrester for Optimal Protection
Customizable High Bearing Voltage Surge Arrester for Optimal Protection
Customizable High Bearing Voltage Surge Arrester for Optimal Protection

Product Parameters

Exploring the Key Characteristics of Jacket Materials and Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Optimal Working Environment:

Meticulously crafted for flawless performance indoors and outdoors;

Operates effectively at awe-inspiring altitudes up to 3000m;

Withstands ambient temperatures from a crisp -40°C to a soothing +60°C;

Harmonizes with power supply frequencies ranging from a stable 48Hz to a lively 62Hz;

Guarantees that the power frequency voltage between terminals stays within ideal thresholds for extended longevity.

Built to resist seismic activities with intensity not surpassing 8 degrees.

Skillfully engineered to brave outdoor wind speeds soaring up to 35 meters/second;

Important Notes:

If you encounter conditions exceeding these standard parameters, our team is ready to offer custom solutions tailored to your needs.

Core Technical Parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Notice: Constructed with a robust Polymeric build for enhanced durability

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Notice: Accompanied by Porcelain Series Gap specifications

Installation Guidelines

(1) Before installation, check the nameplate to ensure the arrester's system rated voltage corresponds with the installation site's system voltage;

(2) Offers installation versatility with options for suspension or vertical arrangement. For vertical setup, refrain from using the arrester as a load-supporting insulator;

(3) Optimize the lead wire length to sustain protective efficacy and minimize equipment stress.

Testing Protocols

  • For bolstering operational reliability, conduct preventive tests every 4-5 years. Focus primarily on measuring U1mA across both terminals of the DC 1mA arrester.
  • Before installation, affirm that the U1mA voltage is at least 97% of the original factory value and ensure this data is meticulously recorded.
  • During preventive maintenance, ascertain that the U1mA voltage does not dip below 26kV.
  • Important Note: Actively minimize harmonic elements in the DC power supply during tests. Subpar waveforms might lead to low U1mA readings.
  • Newly launched, the 10kV synthetic insulated zinc oxide arrester for power distribution has triumphed through rigorous lab tests, proving its steadfast performance under outdoor line voltage for 15 months. Findings declare: exceptional jacket quality, remarkable arrester structural reliability, and unwavering core stability. Augmented by annual performance data from 2,000 units, this product assures unmatched protection, lower failure occurrences, and maintenance-free functionality throughout its operational lifespan.Customizable High Bearing Voltage Surge Arrester for Optimal Protection
Certifications

Customizable High Bearing Voltage Surge Arrester for Optimal Protection

Company Profile

Customizable High Bearing Voltage Surge Arrester for Optimal Protection

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier