Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions

Product Details
Customization: Available
Application: Power, Distrbution
Phase: Single
Still deciding? Get samples of US$ 900/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (19)
  • Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions
  • Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions
  • Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions
  • Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions
  • Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions
  • Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions
Find Similar Products
  • Overview
  • Company Profile
  • Product Description
  • Product Parameters
  • Detailed Photos
  • Certifications
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
CSP
Core
Core-type Transformer
Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001, CCC, CSA/IEEE/Cesi
Usage
Single-phase Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Primary Voltage
12.4/13.2/13.8/34.5kv
Place of Origin
Jiangsu, China
Standard
DOE/IEC60076/IEEE/ANSI/CSA/as/Azs/GOST
Material
Aluminum/Cooper
Input Voltage
Other
Model Number
D
Brand Name
Daelim Belefic
Type
Conventional /Csp Type
Coil Number
2
Coil Structure
Toroidal
Output Voltage
Other
Transport Package
Wooden Case Packing, Container Shipping
Specification
1000.00cm * 1000.00cm * 1000.00cm
Trademark
CHBEB
Origin
China
HS Code
8504210000
Production Capacity
6000pieces/Year

Product Description

Company Profile

Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions

Product Description

Crafted with precision by Daelim, CHBEB's single-phase pole-mounted transformers are your premier choice for stepping down utility distribution voltages from an impressive range of 2400V to 34,500V to user-friendly levels. Whether intended for commercial use at 277V, 240/480V, or industrial applications like 2400V and 4800V, most of our transformers are optimized for single-phase voltages of 120/240V. Versatility is key, as these transformers excel in small substations and can even step up voltages when needed, all with unmatched reliability and performance.

At CHBEB, we offer a comprehensive two-type range of single-phase pole-mounted transformers: the robust conventional type and the advanced Completely Self-Protected (CSP) type. These transformative powerhouses are rated up to 167kVA, ensuring you have the power you need whenever and wherever you need it.

Key Features:

  • High Efficiency: Engineered to meet DOE Energy Efficiency Standards, our transformers not only comply but also surpass ANSI/IEEE and CSA benchmarks, ensuring superior performance and sustainability.
  • Standard Features: Our transformers come equipped with ISO 9001 quality certification. They feature lifting lugs, arrester mounting pads, high-voltage porcelain bushings with eyebolt terminals, low-voltage bushings with matching terminals, and secure low-voltage neutral grounding straps.
  • Self-Protected (CSP) Design: Packed with enhanced protective features, our CSP units boast primary protective links, surge arresters, secondary circuit breakers, emergency overload reset handles, and convenient overload signal lights, all to safeguard your investment.
  • Durability and Safety: Built with a self-venting and resealing cover assembly, our transformers promise enduring safety and reliable operation, protecting your power network for years to come.
Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions
Product Parameters

Operating Environment:

  1. Ambient Temperature: Operating efficiently at a maximum of +40°C and a minimum of -15°C.
  2. Altitude: Designed for altitudes not exceeding 1000m, ensuring performance across varied terrains.
  3. Humidity:
    • Daily average relative humidity: ≤95%
    • Monthly average relative humidity: ≤90%
  4. Seismic Intensity: Expertly built to withstand seismic activities of up to 8 degrees, offering resilience in challenging environments.
  5. Installation Conditions: Ensure an installation environment free from fire hazards, explosions, severe vibrations, chemical corrosion, and heavy pollution for optimal performance.

Technical Data:

Conventional Type Single-Phase Pole Mounted Transformer:

Rated Power High Voltage Low Voltage No Load Losses (W) On Load Losses (W) Weight (kg)
10kVA 34500/19920V 120-240V 36 120 150
15kVA 34500/19920V 120-240V 50 195 210
25kVA 34500/19920V 120-240V 80 290 258
37.5kVA 34500/19920V 120-240V 105 360 340
50kVA 34500/19920V 120-240V 135 500 395
75kVA 34500/19920V 120-240V 190 650 480
100kVA 34500/19920V 120-240V 210 850 583
167kVA 34500/19920V 120-240V 350 1410 680

Completely Self-Protected (CSP) Type Single-Phase Pole Mounted Transformer:

Rated Power High Voltage Low Voltage No Load Losses (W) On Load Losses (W) Weight (kg)
10kVA 34500/19920V 120-240V 50 120 150
15kVA 34500/19920V 120-240V 65 195 205
25kVA 34500/19920V 120-240V 105 290 245
37.5kVA 34500/19920V 120-240V 140 360 335
50kVA 34500/19920V 120-240V 180 500 370
75kVA 34500/19920V 120-240V 250 650 505

Applications: CHBEB single-phase pole-mounted transformers are indispensable in both urban and rural power distribution networks. They provide seamless voltage conversion for residential, commercial, and industrial setups, effectively serving small substations, factories, and various locales demanding precise voltage adjustments.
Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions
Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions

Detailed Photos
Durable 15kVA Load Transformer for Optimal Distribution Needs SolutionsDurable 15kVA Load Transformer for Optimal Distribution Needs SolutionsDurable 15kVA Load Transformer for Optimal Distribution Needs SolutionsDurable 15kVA Load Transformer for Optimal Distribution Needs SolutionsDurable 15kVA Load Transformer for Optimal Distribution Needs SolutionsDurable 15kVA Load Transformer for Optimal Distribution Needs SolutionsDurable 15kVA Load Transformer for Optimal Distribution Needs SolutionsDurable 15kVA Load Transformer for Optimal Distribution Needs SolutionsDurable 15kVA Load Transformer for Optimal Distribution Needs SolutionsDurable 15kVA Load Transformer for Optimal Distribution Needs Solutions
Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions
Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions
Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions
Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions
Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions
Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions

Certifications
Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions

Packaging & Shipping

Durable 15kVA Load Transformer for Optimal Distribution Needs Solutions

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier