Customization: | Available |
---|---|
Breaking Capacity: | 10kv /11kv /12kv/ 24kv/33kv/40.5 |
Operation: | Manual/Electric /Energy-Storage |
Still deciding? Get samples of US$ 1200/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introducing the VS1-12/24/33(ZN63A) - a revolutionary indoor high-voltage vacuum circuit breaker, expertly crafted for use in 12kV, three-phase AC 50Hz systems. This state-of-the-art model is engineered
to integrate smoothly into indoor high-voltage switchgear, featuring an advanced spring operating mechanism that accommodates both manual and electric modes. This guarantees a
full spectrum of capabilities: exceptional protection, precise control, and highly efficient circuit breaking. Perfectly suited for challenging environments like mines, factories, substations, and
switchyards. The device is distinguished by its proficiency in managing frequent operations while skillfully monitoring current loads, ensuring remarkable performance.
Operating Environment
The VS1 boasts a flexible ambient temperature range from -10°C to +40°C, with storage capabilities reaching as low as -30°C;
It operates seamlessly at altitudes up to 1000m;
Exhibiting an outstanding endurance to relative humidity, with daily averages up to 95%, monthly averages up to 90%, and absolute humidity up to 2.2x10³ MPa. Daily water vapor pressure is maintained at ≤1.8x10³ MPa. It is engineered to withstand condensation even under high temperatures;
Peak performance is achieved when ambient temperatures stay below 35°C;
The VS1 is meticulously crafted to excel in environments devoid of fire, explosion hazards, severe pollution, chemical corrosion, or intense vibrations.
Structural Features
Insulating Components
Our VS1 vacuum circuit breaker utilizes ceramic or glass vacuum interrupters with metal bellows, complemented by
cutting-edge vacuum contact materials and high-pressure forming of sealed insulating enclosures. These contacts provide exceptional
dielectric strength, stable pressure, lower contact resistance, and enhanced current-carrying capacity, all while offering
superior arc-extinguishing performance.
Framework
Embracing a progressive modular design, the VS1 vacuum circuit breaker incorporates a sophisticated spring mechanism with vacuum
interrupters encased in a durable tubular insulating framework. Its adaptable design facilitates direct installation or integration into
switchgear cubicles,
making it impeccably suited for electrical distribution, industrial settings, and substations. The enclosure ensures stability and safeguards against
even the most severe environmental conditions, such as intense pollution and humidity.
Performance
The VS1 vacuum circuit breaker stands for reliable, long-lasting performance and boasts a prolonged mechanical and electrical lifespan. It demands
minimal maintenance and is designed to withstand harsh environmental conditions, effortlessly managing humidity, dust, and frequent switching
operations with excellence.
Operating Mechanism
Equipped with a spring-charged operating mechanism, the VS1 vacuum circuit breaker can be easily operated
manually or through electric commands. This reliable mechanism ensures that the circuit breaker remains consistently charged, securely closed, and
opened with unwavering dependability.
Its design emphasizes reliability with fewer mechanical components to ensure smooth operation,
making the VS1 vacuum circuit breaker a paragon of efficiency for frequent operation scenarios, delivering high operational
efficiency with minimal noise and vibration, setting a new standard in the industry.
Working And Operating Principles
Arc Extinguishing Principle
Harnessing the unparalleled power of vacuum as the insulating medium, the VS1 vacuum circuit breaker effortlessly executes arc extinguishing with remarkable finesse. As the contacts part,
the arc is ingeniously compelled to spread and extinguish swiftly, aided by the advanced magnetic field generated within the
vacuum interrupter. This process effectively cools and condenses the arc plasma, ensuring a rapid and reliable arc extinguishing process, resulting in minimal contact wear, thereby assuring stable and reliable operation.
resulting in minimal contact wear and assuring stable and reliable operation.
Energy Storage
The energy storage system of the VS1 vacuum circuit breaker employs a highly efficient motor-driven mechanism to expertly wind
Our state-of-the-art energy storage springs ensure that, once fully charged, the breaker is primed and ready for flawless operation. This cutting-edge technology
has been meticulously designed to guarantee unmatched reliability, providing stable and swift energy release that is crucial during high-stakes switching operations.
Closing Operation
When a closing command is received, the potent energy stored within the closing springs is unleashed, propelling the contacts
together with lightning-fast speed. This state-of-the-art mechanism guarantees a rapid and dependable closing action, perfectly suited for a wide range of critical applications that demand superior operational performance and unwavering reliability.
applications that require superior operational performance and reliability.
Opening Operation
In opening operations, the breaker harnesses the formidable energy stored in the opening springs, which is released instantly upon
receiving an opening command. This swift and powerful release of energy forces the contacts apart, thereby effectively interrupting the
current flow and extinguishing the arc within the vacuum interrupter. This vital action ensures safe, efficient, and effective
circuit breaking, thereby safeguarding your valuable electrical systems with unparalleled precision and reliability.
Maintenance
Our VS1 vacuum circuit breaker is expertly engineered for simplicity in maintenance, offering exceptional durability and robust
performance even in the most demanding operational environments. With regular inspections and minimal maintenance,
you can effortlessly maintain peak functionality, minimize costly downtime, and ensure the continuous reliability of your critical electrical
protection systems, all while optimizing operational efficiency and enhancing overall performance.