Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations
  • Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations
  • Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations
  • Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations
  • Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations
  • Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing Beierbian Group Co., Ltd's revolutionary Zinc Oxide Arrester—an extraordinary advancement in lightning protection technology, crafted for 10kV power distribution systems. This state-of-the-art device is a marvel of innovation, featuring a zinc oxide valve column enhanced with meticulously placed upper and lower electrodes, all encased in premium silicone rubber. This sophisticated construction offers unparalleled features:

  1. Experience the innovative design that expertly resolves sealing challenges that have historically troubled arrester systems. By seamlessly integrating the core and jacket into a cohesive, streamlined unit, it eliminates potential cavities that could lead to detrimental internal breathing issues. This ingenious engineering effectively conquers the technical complexities of preventing moisture ingress into internal components, ensuring unrivaled performance and reliability.
  2. Boasting a robust core with impressive capabilities to withstand internal overvoltage, this arrester exemplifies superior engineering. It showcases remarkable aging resistance, ensuring consistent performance and steadfast protection over time, providing users with assured long-lasting reliability and effectiveness.

Utilizing a specially engineered valve plate combined with optimized core parameters, this device confidently addresses challenges like arc grounding, PT resonance, and a diverse range of operational overvoltages. It operates with unmatched reliability, sustaining performance under normal line voltage and enduring 2.5 to 3 times power frequency overvoltage. Its voltage withstand duration not only meets but far exceeds international standards by 1 to 3 orders of magnitude, offering exceptional safety and unrivaled operational longevity.
Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations

Detailed Photos

Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations

Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations
Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations
Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations
Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations
Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations
Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Meticulously crafted to deliver flawless functionality, be it in the confines of indoor spaces or the expanse of the great outdoors;

Engineered to ensure effective and seamless operation at altitudes that impressively rise up to a remarkable 3000 meters;

Constructed to endure a broad spectrum of ambient temperatures, ranging from a stark and icy -40°C to a warm and inviting +60°C;

Expertly designed for compatibility with power supply frequencies that range from a steady 48Hz to a dynamic and fluctuating 62Hz;

Guarantees that the power frequency voltage applied between terminals remains within optimal limits, ensuring enduring and reliable use throughout its operation.

Engineered to withstand seismic activities with an intensity not exceeding 8 degrees, ensuring robust durability and steadfastness during quakes.

Designed to brave fierce outdoor wind speeds, reaching up to a formidable 35 meters per second with resilience;

Note:

Encountering conditions beyond these standard operational parameters? Our dedicated team is on standby, ready to discuss and provide bespoke solutions tailored to your unique needs.

Main Technical Parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: This product boasts a durable and resilient Polymeric construction, ensuring longevity and robustness.

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Incorporates advanced Porcelain Series Gap specifications for superior performance and reliability.

Installation

(1) Prior to installation, verify the nameplate to ensure the arrester's system rated voltage perfectly aligns with the system voltage at the installation site, guaranteeing optimal performance;

(2) Offers installation flexibility with both suspension or vertical options. For vertical installation, ensure the arrester is not utilized as a load-bearing insulator to maintain integrity;

(3) Optimize lead wire length to sustain protection efficiency and prevent undue stress on the equipment, ensuring long-term operational stability.

Test

  • lTo enhance operational reliability, conducting preventive tests every 4-5 years is strongly advised. These tests should focus primarily on measuring U1mA at both terminals of the DC 1mA arrester.
  • lPrior to installation, it is essential to confirm that the U1mA voltage is at least 97% of the original factory value and meticulously document this data for accuracy and future reference.
  • lDuring preventive maintenance, it is critical to ensure the U1mA voltage does not fall below 26kV, maintaining efficiency and reliability.
  • lNote: Minimize the harmonic components in the DC power supply during tests, as poor waveforms can lead to inaccurately low U1mA readings that affect performance.
  • lOur innovative 10kV synthetic insulated zinc oxide arrester for power distribution has successfully undergone rigorous lab tests, consistently demonstrating its functionality under outdoor line voltage for an impressive duration of 15 months. The results underscore the jacket's superior quality, the arrester’s structural reliability, and the unwavering stability of its core. Coupled with annual performance insights from 2,000 units, this product offers unmatched protection, significantly reduced failure rates, and a maintenance-free experience throughout its lifecycle.Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations
Certifications

Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations

Company Profile

Zinc Oxide Surge Protection for Custom Voltage Arrester Configurations

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier