Capacitor Bank Lightning Protector with User Requirement Customization Options

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of US$ 35/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (19)
  • Capacitor Bank Lightning Protector with User Requirement Customization Options
  • Capacitor Bank Lightning Protector with User Requirement Customization Options
  • Capacitor Bank Lightning Protector with User Requirement Customization Options
  • Capacitor Bank Lightning Protector with User Requirement Customization Options
  • Capacitor Bank Lightning Protector with User Requirement Customization Options
  • Capacitor Bank Lightning Protector with User Requirement Customization Options
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the Zinc Oxide Arrester from Beierbian Group Co., Ltd - an extraordinary leap forward in lightning protection tailored for 10kV power distribution systems. This trailblazing device is a testament to the pinnacle of contemporary engineering, showcasing a state-of-the-art zinc oxide valve column, complemented by meticulously designed upper and lower electrodes. Encapsulated in premium silicone rubber, this assembly promises unparalleled reliability and exceptional performance. With its remarkable features, this product establishes a new industry benchmark:

  1. This innovative design cleverly addresses and overcomes the significant sealing challenges that have long plagued traditional arresters. By seamlessly integrating the core and jacket into a single, compact entity, it eliminates any potential voids that could cause internal breathing issues, thus expertly resolving the technical complications related to moisture ingress within internal components.
  2. Armed with a robust core capable of enduring substantial internal overvoltage, this arrester showcases outstanding resistance to aging. It ensures extended superior performance, providing steadfast protection that withstands the tests of time and environmental challenges with remarkable resilience and trustworthiness.

Employing a precisely engineered valve plate in conjunction with optimized core parameters, this device guarantees top-tier protection. The core is masterfully crafted to combat challenges such as arc grounding, PT resonance, and a wide range of operational overvoltages. It functions with unmatched reliability under line voltage conditions, also enduring 2.5 to 3 times the power frequency overvoltage. Its voltage endurance surpasses international standards by an impressive 1 to 3 orders of magnitude, delivering unrivaled safety and operational longevity, setting a new paradigm for high-performance protection solutions.
Capacitor Bank Lightning Protector with User Requirement Customization Options

Detailed Photos

Capacitor Bank Lightning Protector with User Requirement Customization Options

Capacitor Bank Lightning Protector with User Requirement Customization Options
Capacitor Bank Lightning Protector with User Requirement Customization Options
Capacitor Bank Lightning Protector with User Requirement Customization Options
Capacitor Bank Lightning Protector with User Requirement Customization Options
Capacitor Bank Lightning Protector with User Requirement Customization Options
Capacitor Bank Lightning Protector with User Requirement Customization Options

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

This surge arrester is meticulously crafted to provide unmatched performance in a variety of locations, effortlessly transitioning between both indoor and outdoor settings.

It operates flawlessly even at high altitudes, effortlessly reaching up to an impressive 3000 meters.

Masterfully engineered to function seamlessly across a vast temperature range from a brisk -40°C to a warm +60°C, this product thrives in the harshest chilly conditions or the most pleasant warmth without sacrificing performance.

Intricately engineered to harmonize with power supply frequencies ranging from a stable 48Hz to a lively 62Hz, ensuring perfect compatibility.

Ensures the power frequency voltage between terminals is flawlessly maintained, ensuring long-lasting and uninterrupted operation.

Designed to withstand seismic events up to 8 degrees, this product guarantees remarkable stability and reliability.

Engineered to endure strong outdoor winds up to 35 meters per second, providing steadfast reliability against nature's elements.

Note:

For needs surpassing these standard working boundaries, our skilled team is ready to provide custom solutions tailored precisely to your specifications.

Main technical parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Constructed with durable Polymeric material, enhancing the product's strength and longevity.

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Includes Porcelain Series Gap specification, adding an element of refinement and elegance.

Installation

(1) Before installation, examine the nameplate to confirm that the arrester's rated voltage matches the system voltage at the intended installation location.

(2) Provides versatile installation options with choices for suspension or vertical mounting. For vertical installations, ensure the arrester is not used as a load-bearing insulator.

(3) Adjust the lead wire length for optimal protective efficiency, minimizing stress and ensuring maximum safety for the equipment.

Test

  • lTo enhance operational reliability, conduct preventive tests every 4-5 years, focusing on measuring U1mA at both terminals of the DC 1mA arrester.
  • lBefore installation, confirm that the U1mA voltage is at least 97% of its original factory value, meticulously recording this data for future reference.
  • lDuring preventive maintenance, ensure the U1mA voltage consistently exceeds 26kV.
  • lNote: Reduce harmonic distortions in the DC power supply during tests to prevent low U1mA readings from incorrect waveforms.
  • lThe newly launched 10kV synthetic insulated zinc oxide arrester for power distribution has successfully proven its capabilities in extensive laboratory tests, consistently performing under outdoor line voltage conditions for 15 months. This is a testament to the superior quality of the jacket, the arrester's dependable structure, and robust core stability, supported by annual performance data from 2,000 units. It promises unparalleled protection, exceptionally low failure rates, and maintenance-free operation throughout its entire lifecycle.Capacitor Bank Lightning Protector with User Requirement Customization Options
Certifications

Capacitor Bank Lightning Protector with User Requirement Customization Options

Company Profile

Capacitor Bank Lightning Protector with User Requirement Customization Options

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier