Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, affectionately termed as the 'fuse', is meticulously engineered for outdoor overhead distribution systems. It boasts an impressive rated frequency of 50Hz and a formidable rated voltage of 10kV (12/15/35/40.5). This state-of-the-art device acts as a guardian angel for circuits and electrical equipment, skillfully mitigating overloads and short circuit faults within power systems. In its everyday role, the fuse stands valiantly in series within the power line, perfectly tensioned, with its movable joint securely locked. However, should the line encounter a fault, the fuse heroically blows, releasing the joint, dropping the fuse tube quickly, and severing the circuit. This crucial action serves as a bastion of safety, protecting both line maintenance and equipment. Enhancing the functionality, the load-type fuse incorporates elastic contact and an arc extinguishing cover, ensuring seamless opening and closing of load currents in power systems.
Adherence to Industry Standards: The fuse is crafted to meet an array of rigorous technical standards, including the esteemed GB / T 15166.3 - 2008 for high voltage AC fuses - Part 3: injection fuses, as well as the DL / T 640 - 1997 for outdoor AC high voltage drop-tested fuses and fuse links ordering technical conditions, ensuring top-notch quality and unparalleled reliability.
Working Environment:
Ambient Temperature: A resilient range from -40°C to +40°C, ensuring performance in diverse climatic conditions.
Relative Humidity: Designed to withstand climates with a daily average not exceeding 95%, and a monthly average not surpassing 90%, maintaining functionality in humid environments.
Altitude: Operational efficiency is maintained at altitudes up to 3000m, tailored for high-altitude installations.
Wind Speed: Capable of withstanding outdoor wind speeds up to 34 meters per second, ensuring stability in gale-force conditions.
Installation Site: Ideal for locations devoid of fire risks, explosive hazards, and corrosive chemical gases, while necessitating a well-ventilated setting.
Note: For situations surpassing these outlined conditions, users are invited to engage in personalized consultations with the company.
Technical Parameters
Note: Our company stands ready to provide bespoke products tailored to specific user requirements, ensuring complete satisfaction.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |