User Requirement Arrester Solution for 30kv and 36kv Applications

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of US$ 35/Piece
Request Sample
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (19)
  • User Requirement Arrester Solution for 30kv and 36kv Applications
  • User Requirement Arrester Solution for 30kv and 36kv Applications
  • User Requirement Arrester Solution for 30kv and 36kv Applications
  • User Requirement Arrester Solution for 30kv and 36kv Applications
  • User Requirement Arrester Solution for 30kv and 36kv Applications
  • User Requirement Arrester Solution for 30kv and 36kv Applications
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Introducing the revolutionary Zinc Oxide Arrester by Beierbian Group Co., Ltd – a beacon of modern lightning protection for 10kV power distribution systems. This cutting-edge device is a testament to advanced engineering, showcasing a state-of-the-art zinc oxide valve column and meticulously designed upper and lower electrodes. Encased in premium silicone rubber, it offers unparalleled reliability and performance. This product redefines industry standards with its exceptional features:

  1. This pioneering design adeptly addresses the challenging sealing issues traditionally associated with arresters. By ingeniously merging the core and jacket into a single, streamlined unit, it eradicates potential cavity-induced internal breathing problems, thereby effectively resolving moisture ingress issues within the internal components.
  2. Featuring a robust core capable of withstanding significant internal overvoltage, this arrester offers remarkable aging resistance. It ensures consistently high-level performance, delivering steadfast protection that stands the test of time and environmental challenges with exceptional resilience and reliability.

Through a meticulously engineered valve plate and optimized core parameters, this device guarantees superior protection. The core is expertly crafted to tackle challenges such as arc grounding, PT resonance, and various operational overvoltages. It operates with unparalleled reliability under line voltage conditions while enduring 2.5 to 3 times the power frequency overvoltage. Its voltage endurance surpasses international standards by an extraordinary 1 to 3 orders of magnitude, providing unmatched safety and operational longevity, setting a new benchmark for high-performance protection solutions.
User Requirement Arrester Solution for 30kv and 36kv Applications

Detailed Photos

User Requirement Arrester Solution for 30kv and 36kv Applications

User Requirement Arrester Solution for 30kv and 36kv Applications
User Requirement Arrester Solution for 30kv and 36kv Applications
User Requirement Arrester Solution for 30kv and 36kv Applications
User Requirement Arrester Solution for 30kv and 36kv Applications
User Requirement Arrester Solution for 30kv and 36kv Applications
User Requirement Arrester Solution for 30kv and 36kv Applications

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

This surge arrester is a masterpiece of engineering, designed to ensure exceptional performance in any setting, effortlessly accommodating both indoor and outdoor environments.

It excels at high altitudes, confidently operating up to an awe-inspiring 3000 meters without a hitch.

Meticulously engineered to function seamlessly across a broad temperature range of -40°C to +60°C, this product endures the harshest or warmest climates without faltering.

Precisely aligned to synchronize perfectly with power supply frequencies spanning from a steady 48Hz to a dynamic 62Hz, guaranteeing seamless compatibility.

Ensuring the power frequency voltage between terminals is consistently optimized, this product promises enduring reliability and uninterrupted use.

Constructed to withstand seismic disturbances up to 8 degrees in intensity, this product guarantees unmatched stability and resilience.

Expertly crafted to defy powerful outdoor winds reaching up to 35 meters per second, providing steadfast reliability against the elements.

Note:

For requirements that surpass these standard operating limits, our skilled team is ready to offer tailored solutions to meet your specific needs.

Main technical parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Featuring a durable Polymeric construction, the product's resilience is markedly enhanced.

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Incorporates a refined Porcelain Series Gap specification, lending an air of elegance and sophistication.

Installation

(1) Before installation, inspect the nameplate to confirm that the arrester's rated voltage matches the system voltage at the intended installation site.

(2) Provides versatile installation options with choices for suspension or vertical mounting. Ensure that in vertical installations, the arrester is not used as a load-bearing insulator.

(3) Adjust the lead wire length for optimal protection efficiency, reducing stress and enhancing equipment safety.

Test

  • lTo enhance operational reliability, conduct preventive tests every 4-5 years, focusing on measuring U1mA at both ends of the DC 1mA arrester.
  • lBefore installation, ensure the U1mA voltage is at least 97% of the original factory value, carefully recording this data for future reference.
  • lDuring preventive maintenance, confirm that the U1mA voltage consistently stays above 26kV.
  • lNote: Minimize harmonic distortions in the DC power supply during tests to avoid low U1mA readings due to erroneous waveforms.
  • lThe newly introduced 10kV synthetic insulated zinc oxide arrester for power distribution has demonstrated its excellence in extensive laboratory testing, continuously operating under outdoor line voltage conditions for 15 months. This achievement showcases the jacket's exceptional quality, the arrester's reliable design, and robust core stability. Supported by annual performance data from 2,000 units, it ensures unrivaled protection, exceptionally low failure rates, and maintenance-free performance throughout its lifespan.User Requirement Arrester Solution for 30kv and 36kv Applications
Certifications

User Requirement Arrester Solution for 30kv and 36kv Applications

Company Profile

User Requirement Arrester Solution for 30kv and 36kv Applications

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier