Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
  • Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
  • Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
  • Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
  • Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
  • Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Packaging & Delivery

Package Size
45.00cm * 55.00cm * 38.00cm
Package Gross Weight
20.000kg

Product Description

Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
Product Description

Introducing the (H)GWBEB type outdoor high-voltage isolation switch, a pinnacle of engineering crafted for excellence. Known as an isolation disconnect switch, this high-performance device is primarily designed for application on 10(12, 15, 24)kV high voltage power transmission and distribution lines. It is engineered to effortlessly open and close single-phase or three-phase circuits, managing the presence of voltage without bearing a load. Its resilient construction ensures unmatched reliability.

The switch is adept at single-phase operation within three-phase line systems, boasting a design of simplicity, cost-efficiency, and user-friendliness. Available rated currents span 200, 400, 600, 800, 1000, to 1250 amps, offering versatility to suit diverse power needs. The switch architecture encompasses a base, robust post insulators, conductive components, and a mechanical section. Employing a sophisticated gate knife mechanism for circuit management, each phase's gate knife integrates dual conductive blades with external compression springs on either side. The adjustable spring height ensures the precise contact pressure necessary for optimal switch gate knife performance. For seamless operation, an insulated hook stick facilitates both opening and closing actions, complemented by an innovative self-locking device.

Working Environment:

Altitude not exceeding 1000 meters, ensuring optimal performance and reliability.

Ambient temperature: maximum not above +40°C; minimum not below -30°C; maintaining operability in diverse climatic conditions.

Outdoor wind speed not exceeding 35 meters/second; engineered to withstand challenging weather scenarios.

Seismic intensity not exceeding 8 degrees; ensuring stability in earthquake-prone regions, with the installation site free from frequent severe vibrations.

The installation site should remain devoid of gases, chemical deposits, salt mist, dust, dirt, or other explosive or corrosive environments that could compromise the switch's insulation and conductivity.

Note:

WHEN THE ABOVE NORMAL USE CONDITIONS ARE EXCEEDED, USERS ARE ENCOURAGED TO NEGOTIATE WITH THE COMPANY FOR TAILORED SOLUTIONS.

 

Installation, Use and Adjustment

Pre-installation work

  1. Meticulously remove dust and contaminants from all components, and gently clean the insulating porcelain bottle surface.
  2. Scrub the wiring surface of the ground screw to ensure optimal connectivity.
  3. Apply a protective layer of industrial Vaseline to the rotating parts and contact areas to enhance durability.
  4. Inspect the contact surface and adjust the compression spring height to ensure the contact pressure is in accordance with Table II, optimizing performance.
  5. This switch is exclusively designed for hoisting applications and works seamlessly with transformers on the line, ensuring efficient energy distribution.
  6. The rated current of this switch ranges from 200-400 ampere hours, utilizing generally three mounting holes. For 600-1000A applications, three mounting holes are also employed, emphasizing stability and efficiency.

Conduct an annual inspection to ensure the switch's optimal operation, focusing on these vital components:
Remove any dirt from conductive parts, contact surfaces, and the insulating porcelain bottle surface, maintaining pristine condition.

Thoroughly inspect all components for damage, with particular focus on identifying any damage or cracks in the insulating porcelain bottle, ensuring safety and performance.

Verify that the contact surface of the conductive part remains in excellent condition, ensuring reliable connectivity.


Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model

Detailed Photos

 

Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model


Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model

Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model
Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model

 

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Outdoor Isolation Disconnect Switch – High Voltage Load Break Switch ModelOutdoor Isolation Disconnect Switch – High Voltage Load Break Switch Model