Customization: | Available |
---|---|
Type: | High-voltage |
Structure: | Three-column Disconnector |
Still deciding? Get samples of US$ 800/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The ZW32-12 outdoor high voltage vacuum circuit breaker, affectionately known as the 'circuit breaker,' is a premier outdoor distribution switchgear engineered to operate seamlessly at a rated voltage of 12kV, featuring a robust three-phase AC of 50Hz. This remarkable circuit breaker is masterfully designed to manage the interruption and connection of load current, overload current, and short circuit current within the power grid with exceptional precision and reliability. It boasts cutting-edge overload and short circuit protective capabilities, seamlessly fulfilling control and measurement specifications while offering sophisticated remote control and monitoring functionalities. Its extensive application spans substations, industrial settings, and mining enterprise distribution systems, providing unparalleled control and operation, ideal for environments that demand frequent operations.
Structural features:
Crafted with precision, the circuit breaker showcases a three-phase pillar dry design, ensuring optimal performance and durability;
Engineered with a fully enclosed structure, it provides superior sealing, exceptional moisture resistance, and anti-condensation properties, making it the perfect choice for high-temperature and humid regions, ensuring long-lasting reliability and performance;
Employs state-of-the-art vacuum arc extinguishing technology, guaranteeing outstanding insulation reliability and efficiency;
Delivers flawless opening and closing performance, ensuring maximum safety with no risk of combustion or explosion, providing peace of mind to users;
Compact, lightweight, requiring no maintenance, and promises an impressive lifespan, making it a cost-effective and reliable solution;
Versatility in operation is its hallmark, with manual, electric, or remote control options available, catering to a wide range of user preferences and needs;
The operating mechanism is meticulously sealed at the base of the switch box, effectively safeguarding against outdoor environmental corrosion, ensuring longevity and optimal functionality;
Showcases a novel, simplistic design with a restless mechanism that ensures reliable dynamic performance, compact form, and an astounding service life of up to 10,000 cycles, setting a new standard in durability and efficiency.
Main technical parameters:
No |
Name |
Unit |
Data |
|||
1 |
Rated voltage |
kV |
12 |
|||
2 |
Rated current |
A |
630 |
1250 |
||
3 |
Rated frequency |
Hz |
50 |
|||
4 |
Rated insulation level |
1min power frequency withstand voltage |
Dry test |
/ |
42/48(fracture) |
|
Wet test |
34 |
|||||
Secondary circuit to ground |
2 |
|||||
Lightning impulse withstand voltage (peak value) |
75/85(fracture) |
|||||
5 |
Rated short circuit making current (peak value) |
kA |
50 |
63 |
||
6 |
Rated short time withstand current |
kA |
20 |
25 |
||
7 |
Rated peak withstand current |
kA |
50 |
63 |
||
8 |
Breaking times of rated short circuit breaking current |
Times |
30 |
|||
9 |
Rated short circuit duration |
s |
4 |
|||
10 |
Rated operating voltage and rated voltage of auxiliary circuit |
V |
DC220,AC220 ,AC/DC220 |
|||
11 |
Rated operation sequence |
/ |
Off-0.3s-on-off-180s-on-off |
|||
12 |
Rated current of over current trip |
A |
5 |
|||
13 |
Mechanical life |
second |
10000 |
|||
14 |
Allowable wear accumulative thickness of moving and static contacts |
mm |
3 |
|||
15 |
Rated current of over current release |
A |
5 |
|||
16 |
Current ratio of current transformer |
/ |
200/5 400/5 600/5 |
|||
17 |
Contact opening distance |
mm |
9±1 |
|||
18 |
Contact overtravel |
mm |
2±0.5 |
|||
19 |
Average opening speed |
m/s |
1.2±0.3 |
|||
20 |
Average closing speed |
m/s |
0.6±0.2 |
|||
21 |
Opening time |
ms |
≤40 |
|||
22 |
Closing time |
ms |
20~45 |
|||
23 |
Closing bounce time |
ms |
≤2 |
|||
24 |
Asynchrony of three phase closing and opening |
mm |
≤2 |
|||
25 |
Three phase circuit resistance |
μΩ |
≤80 Band isolation≤120 |