(H) RW(F) series outdoor high voltage AC drop fuse, affectionately referred to as the 'fuse,' is crafted for excellence in outdoor overhead distribution systems, boasting a rated frequency of 50Hz and a formidable voltage range of 10kV (12/15/35/40.5). This innovative device acts as a guardian, diligently shielding circuits and electrical equipment from overloads or short circuit disruptions in the power system. In routine operation, the fuse integrates seamlessly into the power line, remaining taut and steadfast with the movable joint securely anchored. However, in the event of a system anomaly, the fault current triggers the fuse to react, unleashing its protective prowess. The movable joint unlocks, allowing the fuse tube to swiftly disconnect, decisively severing the circuit to ensure the utmost safety during line and equipment maintenance. Enhanced with an elastic contact and arc extinguishing cover, the load type fuse transcends the ordinary, empowering you to control load currents within the power system with ease and precision.
Our fuse adheres to the pinnacle of technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses - Part 3: injection fuses, as well as DL / T 640 - 1997 for outdoor AC high voltage drop-tested fuses and fuse links ordering technical conditions.
Working Environment:
Ambient temperature: Embrace a resilience that thrives between -40°C and +40°C;
Relative humidity: Withstand daily averages up to 95% and monthly averages up to 90%;
Operates flawlessly at altitudes up to 3000 meters;
Defies the winds withstanding speeds up to 34 meters/second;
Installation site: Specifically designed for areas free from fire, explosion hazards, chemical corrosive gases, and in well-ventilated locations.
Note: Should your conditions surpass normal usage boundaries, our team is ready to collaborate on customized solutions.
Technical parameters
Note: Our company is equipped to tailor products to meet your specific requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |