Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse (hereinafter referred to as "fuse") is expertly crafted for outdoor overhead distribution systems operating at a rated frequency of 50Hz and rated voltage of 10kV (12/15/35/40.5). Designed as an indispensable protective element, this fuse safeguards circuits or electrical equipment against overload and short circuit faults in power systems. During normal operation, the fuse is securely connected in series within the power line, remaining in a tensioned and locked position. Upon line failure, the fault current triggers the fuse to blow, releasing the movable joint, rapidly dropping the fuse tube, and efficiently cutting off the circuit. This action provides vital safety protection for the maintenance of both line and equipment. The load type fuse is enhanced with elastic contact and an arc extinguishing cover, permitting efficient opening and closing of the load current within the power system.
The fuse is meticulously designed to meet stringent technical standards such as GB / T 15166.3 - 2008 high voltage AC fuses - Part 3: injection fuses, along with DL / T 640 - 1997 outdoor AC high voltage drop tested fuses and fuse links ordering technical conditions.
Working Environment:
The ambient temperature ranges from a chilly -40°C to a warm +40°C, ensuring resilience across diverse climates;
Relative humidity maintains a daily average below 95%, with a monthly average not exceeding 90%, ensuring optimal performance;
The installation altitude must be below 3000m to guarantee functionality and safety;
Outdoor wind speed should not surpass a brisk 34 meters/second, safeguarding structural integrity;
Installation site requirements: It must be free of fire, explosion hazards, chemical corrosive gases, and must be well-ventilated to ensure safety and efficiency.
Note: Should the above normal use conditions be exceeded, users are welcome to negotiate with the company for tailored solutions.
Technical Parameters
Note: Our company is pleased to offer products customized to user specifications.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |