Versatile Surge Arrester Solutions with Customizable Voltage and Protection

Product Details
Customization: Available
Type: Power Source Arrester
Structure: Zinc Oxide Arrester
Still deciding? Get samples of US$ 35/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Versatile Surge Arrester Solutions with Customizable Voltage and Protection
  • Versatile Surge Arrester Solutions with Customizable Voltage and Protection
  • Versatile Surge Arrester Solutions with Customizable Voltage and Protection
  • Versatile Surge Arrester Solutions with Customizable Voltage and Protection
  • Versatile Surge Arrester Solutions with Customizable Voltage and Protection
  • Versatile Surge Arrester Solutions with Customizable Voltage and Protection
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
YH series
Installation
According to Customer Requirements
Application
AC/DC System/Power Plants/Substation
Size
According to Customer Requirements
Operation Voltage
3 - 36kv
Shape
According to Customer Requirements
Material
ZnO
Certification
ROHS, ISO9001, CCC
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Voltage Customizable
30kv 33kv 36kv
Transport Package
Pallet
Trademark
CHBEB
Origin
China
HS Code
8535400000
Production Capacity
50000 Pieces/Quarter

Product Description

Product Description

Behold the Zinc Oxide Arrester from Beierbian Group Co., Ltd—a groundbreaking and meticulously sealed marvel in lightning protection, designed specifically for 10kV power distribution systems. This revolutionary device features an expertly crafted zinc oxide valve column, paired with upper and lower electrodes, all encapsulated within superior silicone rubber. Experience the pinnacle of protection with these unmatched features:

  1. This pioneering design effectively tackles and resolves the sealing issues commonly faced by traditional arresters. By ingeniously merging the core and jacket into a unified, compact structure, it eliminates cavities that could cause internal breathing problems, thereby adeptly addressing the technical challenges of moisture ingress prevention in internal components.
  2. With a robust core designed to withstand significant internal overvoltage, this arrester is the epitome of durability, showcasing superb aging resistance. It promises consistent performance and steadfast protection over time, ensuring peace of mind and reliability.

Engineered with a specially designed valve plate and optimized core parameters, this device ensures the core can handle challenges such as arc grounding, PT resonance, and diverse operational overvoltages. Operating with exceptional dependability, it endures line voltage and handles 2.5 to 3 times power frequency overvoltage. Its voltage withstand duration exceeds international standards by 1 to 3 orders of magnitude, guaranteeing unmatched safety and operational longevity.
Versatile Surge Arrester Solutions with Customizable Voltage and Protection

Detailed Photos

Versatile Surge Arrester Solutions with Customizable Voltage and Protection

Versatile Surge Arrester Solutions with Customizable Voltage and Protection
Versatile Surge Arrester Solutions with Customizable Voltage and Protection
Versatile Surge Arrester Solutions with Customizable Voltage and Protection
Versatile Surge Arrester Solutions with Customizable Voltage and Protection
Versatile Surge Arrester Solutions with Customizable Voltage and Protection
Versatile Surge Arrester Solutions with Customizable Voltage and Protection

Product Parameters

Main Characteristics Of Jacket Materials And Product Usage Environment:

Item

Unit

Norm

Shore Hardness A

/

60

Tensile Strength

mpa

≥35

Breaking Elongation

%

≥250

Oxygen Index

/

45

Resistivity

Ω.m

≥1×1013

Breakdown Strength

MV/m

≥25

Tracking

kV

4.5

Durability

Not less than 20 years

Working Environment:

Meticulously crafted for flawless performance whether indoors or outdoors, our product thrives in diverse environments;

Operates stunningly at altitudes soaring up to an impressive 3000 meters;

Designed to endure ambient temperature extremes from a frosty -40°C to a warm +60°C, ensuring reliability in various climates;

Effortlessly accommodates power supply frequencies ranging from a stable 48Hz to a versatile 62Hz;

Guarantees that power frequency voltage applied between terminals remains perfectly within optimal boundaries for extended use and durability.

Expertly designed to withstand seismic activities up to 8 degrees in intensity, ensuring operational stability;

Built with resilience to withstand outdoor wind forces up to 35 meters per second, providing steadfast performance;

Note:

For conditions exceeding these operational parameters, our dedicated team is ready to offer bespoke solutions tailored to your needs.

Main technical parameters

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA reference voltage
kV not less than

The residual voltage under nominal discharge current
kV (Crest) not greater than

Steep wave impact residual voltage
kV (Crest) not greater than

2ms square wave flow capacity
A

Operation Place

YH5WS-3.8/17

3

3.8

2.0

7.5

17.0

19.6

100

 

Distribution Type

YH5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

YH5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

YH5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

YH5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

YH5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

YH5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

YH5WS-17/45

10

17

13.6

25.0

45.0

/

250

YH10WS-17/45

10

17

13.6

25.0

45.0

/

400

YH5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

YH5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

YH5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

YH5WZ-42/134

35

42

23.4

73

134

154

150

YH5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

YH5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

YH5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH5WZ-51/134

35

51

40.8

73.0

134

154

400

YH10WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

YH10WZ-51/134

35

51

40.8

73.0

134

154

400

YH5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

YH5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

YH5WR-10/27

6

10

8.0

14.4

27.0

/

400

YH5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

YH5WR 17/45

10

17

13.6

24.0

45.0

/

400

YH5WX-51/134

35

51

40.8

73

134.0

154

400

Line type

YH1.5W-30/80

35

30

24

44

80.0

/

600

Neutral Type

Note: Showcasing a strong Polymeric build, enhancing durability and protection;

Model

Nominal Voltage

(rms)

Rated Voltage OArrester

(rms)

Continuous Operating Voltage

(rms)

DC 1mA Reference Voltage
kV Not Less Than

The Residual Voltage Under Nominal Discharge Current
kV (Crest)
Not Greater Than

Steep Wave Impact Residual Voltage
kV (Crest)
Not Greater Than

2ms Square Wave Flow Capacity
A

Operation Place

Y5WS-5/15

3

5

4.0

7.5

15.0

17.3

150

Distribution Type

Y5WS-7.6/30

6

7.6

4.0

15.0

15.0

34.5

100

Y5WS-10/30

6

10

8.0

15.0

30.0

34.6

150

Y5WS-12.7/50

10

12.7

10

26.0

50.0

57.5

100

Y5WS-16.5/50

10

16.5

12.7

26.0

50.0

57.5

100

Y5WS-17/50

10

17

13.6

26.0

50.0

57.5

150

Y5WZ-5/13.5

3

5

4.0

7.2

13.5

15.5

200

Power Station Type

Y5WZ-7.6/27

6

7.6

4.0

14.4

27.0

31.0

150

Y5WZ-10/27

6

10

8.0

14.4

27.0

31.0

200

Y5WZ-42/134

35

42

23.4

73

134

154

150

Y5WZ-12.7/45

10

12.7

6.6

24.0

45.0

51.8

150

Y5WZ-16.5/45

10

16.5

13.2

24.0

45.0

51.8

150

Y5WZ-17/45

10

17

13.6

24.0

45.0

51.8

200

Y5WZ-51/134

35

51

40.8

73.0

134

154

400

Y5WR-5/13.5

3

5

4.0

7.2

13.5

/

400

Capacitive Type

Y5WR-7.6/27

6

7.6

4.0

13.8

27.0

/

400

Y5WR-10/27

6

10

8.0

14.4

27.0

/

400

Y5WR-12.7/45

10

12.7

6.6

23.0

45.0

/

400

Y5WR-17/45

10

17

13.6

24.0

45.0

/

400

Y1.5W-0.28/1.3

0.22

0.28

0.24

0.6

1.3

/

75

Low Voltage

Y1.5W-0.5/2.6

0.38

0.5

0.24

1.2

2.6

/

75

Note:Porcelain

Model

 

Nominal Voltage
(Valid values)

 

Rated Voltage Of Arrester
(Valid values)

 

The Wave Front

Steepness Of The Shock Discharge

 

DC 1mA Reference Voltage

kV Not Less Than

 

1.2/50 Impulse Discharge Voltage

Not Greater Than

 

Wavefront Impulse

Discharge Voltage

 

kV Not Greater Than

The Residual Voltage Under Nominal Discharge

Current 8/20μs

 

kV Not Greater Than

 

2000μs Square

Wave Flow Capacity

 

4/10μs Impulse

Current Capacity

Y5CS-7.6/27

6

7.6

63

16

35

43.8

27

75

25

Y5CZ-7.6/24

6

7.6

63

16

30

37.5

24

150

40

Y5CS-12.7/45

10

12.7

106

26

50

62.5

45

75

25

Y5CS-12.7/41

10

12.7

106

26

45

56.5

41

200

40

Y5CZ-42/124

35

42.0

343

82

134

168

124

200

40

Note: Incorporates Porcelain Series Gap specification for superior performance;

Installation

(1) Before installation, verify the nameplate to confirm the arrester’s system rated voltage matches the system voltage at the installation site;

(2) Provides installation flexibility with options for suspension or vertical installation. For vertical set-up, ensure the arrester is not used as a load-bearing insulator;

(3) Optimize the length of the lead wire to maximize protection efficiency and reduce stress on the equipment.

Test

  • lTo enhance operational reliability, conduct preventive tests every 4-5 years. Focus on measuring U1mA at both terminals of the DC 1mA arrester for optimal performance.
  • lBefore setup, check that the U1mA voltage is at least 97% of its original factory value and carefully document this crucial data.
  • lDuring preventive maintenance, ensure the U1mA voltage remains no less than 26kV to maintain effectiveness.
  • lNote: Minimize harmonic components in the DC power supply during tests. Poor waveforms can lead to inaccurately low U1mA readings.
  • lThe newly launched 10kV synthetic insulated zinc oxide arrester for power distribution has aced rigorous lab tests, proving its unyielding reliability under outdoor line voltage for 15 months. Test results highlight: superior jacket quality, reliable arrester structure, and robust core stability. Supported by annual data from 2,000 units, this product delivers outstanding protection, reduced failure rates, and a maintenance-free lifecycle.Versatile Surge Arrester Solutions with Customizable Voltage and Protection
Certifications

Versatile Surge Arrester Solutions with Customizable Voltage and Protection

Company Profile

Versatile Surge Arrester Solutions with Customizable Voltage and Protection

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier