Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse (hereinafter referred to as "fuse") is a cutting-edge protective solution for outdoor overhead distribution systems. With a rated frequency of 50Hz and a versatile range of rated voltages—10kV, 12, 15, 35, and 40.5—it stands as the ultimate safeguard for circuits and electrical equipment against overloads and short-circuits. The fuse is meticulously designed to integrate directly into the power line, maintaining a tensioned state with a secure movable joint. Upon system faults, the fault current triggers the fuse to blow, releasing the joint and swiftly dropping the fuse tube, thereby breaking the circuit and ensuring comprehensive safety for maintenance operations. Enhanced with an elastic contact and an arc extinguishing cover, this load type fuse excels in opening and closing load currents within the power system, setting a new standard in safety protection.
The fuse is crafted to meet rigorous technical standards such as GB / T 15166.3 - 2008 High Voltage AC Fuses - Part 3: Injection Fuses, and DL / T 640 - 1997 Outdoor AC High Voltage Drop Tested Fuses, as well as the specific fuse links ordering technical conditions, ensuring reliability and performance.
Working Environment:
Ambient temperature: Ranging from -40°C to +40°C, ensuring adaptability in extreme weather conditions;
Relative humidity: The daily average shall not exceed 95%, while the monthly average remains below 90%, maintaining optimal functionality;
The installation altitude should not surpass 3000 meters, affirming operational efficiency at high elevations;
Outdoor wind speed should not exceed 34 meters per second, ensuring stability and durability against strong winds;
Installation site: Should be free from fire, explosion hazards, chemical corrosive gases, and must be a well-ventilated location, prioritizing safety and performance.
Note: If the standard conditions for normal use are surpassed, users are encouraged to engage in discussions with the company for tailored solutions.
Technical Parameters
Note: Our company proudly offers the capability to customize products according to your precise requirements, ensuring a perfect fit for your needs.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |