Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, affectionately known as the "fuse," stands as a beacon of protection for outdoor overhead distribution systems. With a rated frequency of 50Hz and a robust voltage spectrum of 10kV(12/15/35/40.5), this fuse is a guardian against overloads and short circuits. Seamlessly integrated into the power line, the fuse remains tensioned with its movable joint firmly locked during normal operation. When a fault arises, the resultant current causes the fuse to blow, unlocking the joint and swiftly dropping the fuse tube. This rapid action effectively severs the circuit, safeguarding both line and equipment maintenance. Enhanced with an elastic contact and an arc extinguishing cover, our load-type fuse excels at handling load currents with grace.
Meticulously crafted, the fuse adheres to the pinnacle of industry standards including GB / T 15166.3 - 2008 high voltage AC fuses - Part 3: injection fuses, as well as DL / T 640 - 1997 standards for outdoor AC high voltage drop-tested fuses and fuse links. These stringent guidelines ensure an unwavering promise of quality and reliability.
Working Environment:
Capable of withstanding a vast range of temperatures, from the icy chills of -40°C to the balmy warmth of +40°C;
The humidity is no challenge, as it operates optimally with a daily average relative humidity not exceeding 95%, and a monthly average of no more than 90%;
Standing tall and unyielding, it is designed to function flawlessly at altitudes not exceeding 3000 meters;
Engineering prowess ensures resilience against winds whipping at speeds up to 34 meters per second;
Installation site: perfectly suited for environments free of fire, explosion hazards, chemical corrosive gases, and where ventilation is ample.
Note: For conditions exceeding these normal parameters, users are encouraged to engage in dialogue with our company to explore customizable solutions.
echnical parameters
Note: Tailoring to your specifications, our company is prepared to supply products designed to meet your unique requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |