Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) Series Outdoor High Voltage AC Drop Fuse, affectionately known as the 'fuse', is meticulously designed to safeguard outdoor overhead distribution systems, boasting an impressive rated frequency of 50Hz and rated voltage options of 10kV (12/15/35/40.5). Serving as a vital protective component, it vigilantly oversees the circuit or electrical equipment, stepping in during overloads or short circuit disruptions. Under normal conditions, the fuse is seamlessly integrated into the power line, maintaining a tensioned state while securely locked. In the event of a line failure, the fault current triggers the fuse to blow, gracefully releasing the movable joint, promptly dropping the fuse tube, and thereby ensuring the circuit is safely severed. This mechanism provides critical safety protection, facilitating maintenance of both the line and equipment. Enhancing the standard design, our load type fuse incorporates an elastic contact and an arc extinguishing cover, crafted specifically for efficient opening and closing of the load current within the power system.
Our fuses adhere rigorously to distinguished technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses, Part 3: injection fuses, as well as DL / T 640 - 1997 for outdoor AC high voltage drop-tested fuses and fuse links ordering technical conditions, assuring you of their superior safety and reliability.
Working Environment:
Ambient temperature range: from a chilling -40°C to a warm +40°C;
Relative humidity: the daily average does not exceed 95%, while the monthly average lingers below 90%;
Operating effectively at altitudes of up to 3000m;
Designed to withstand outdoor wind speeds not exceeding 34 meters per second;
Installation site specifications demand a safe haven free of fire, explosion hazards, chemical corrosive gases, in well-ventilated locales.
Note: Should your environmental conditions exceed the standard specifications, feel free to engage in a tailored negotiation with us.
Technical parameters
Note: Our company is poised to tailor product offerings to meet specific user requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |