Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of US$ 140/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Outdoor Load Break Disconnector with High Isolation Voltage Specifications
  • Outdoor Load Break Disconnector with High Isolation Voltage Specifications
  • Outdoor Load Break Disconnector with High Isolation Voltage Specifications
  • Outdoor Load Break Disconnector with High Isolation Voltage Specifications
  • Outdoor Load Break Disconnector with High Isolation Voltage Specifications
  • Outdoor Load Break Disconnector with High Isolation Voltage Specifications
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Outdoor Load Break Disconnector with High Isolation Voltage Specifications
Product Description

Introducing the (H)GWBEB type Outdoor High-Voltage Isolation Switch – an unparalleled isolation disconnect switch crafted for impeccable performance on 10(12, 15, 24)kV high voltage power transmission and distribution lines. This distinguished device is engineered to seamlessly open and close single-phase or three-phase circuits even with voltage present, ensuring top-line efficiency and reliability.

Designed for single-phase excellence in three-phase line systems, this switch stands out with its simplistic structure, budget-friendly nature, and user-friendly operation. With rated currents of 200, 400, 600, 800, 1000, and 1250 amps, these switches boast a formidable construction comprising a sturdy base, reliable post insulators, and enduring conductive and mechanical parts. The sophisticated gate knife structure guarantees smooth circuit operations. Every phase's gate knife showcases dual conductive blades, reinforced by external compression springs on either side. Tailoring the spring height achieves the precise contact pressure essential for flawless switch operation. Operable with an insulated hook stick for seamless opening and closing, it also features an ingenious self-locking device for added safety.

Working Environment:

Optimal operation at altitudes not exceeding 1000 meters;

Perfect performance within an ambient temperature range from a soaring +40°C to a chilly -30°C;

Thrives in outdoor conditions with wind speeds up to 35 meters/second;

Withstands seismic intensities up to 8 degrees; ideally suited for installation sites free from frequent severe vibrations.

The installation site must be devoid of gases, chemical residues, salt mist, dust, dirt, or any other explosive or corrosive elements that could significantly impair the switch's insulation and conductivity.

Note:

SHOULD THE STANDARD OPERATING CONDITIONS BE SURPASSED, USERS ARE ENCOURAGED TO DISCUSS WITH THE COMPANY FOR A CUSTOMIZED SOLUTION.

Installation, Use, and Adjustment

Pre-installation work

  1. Begin by meticulously removing dust and dirt from all components, ensuring the insulating porcelain bottle surfaces are flawlessly clean.
  2. Thoroughly scrub the ground screw's wiring surface to ensure optimal connectivity.
  3. Coat rotating parts and contact areas with a protective layer of industrial Vaseline for enhanced longevity.
  4. Inspect contact surfaces and fine-tune the compression spring height to meet the standards detailed in Table II, ensuring optimal contact pressure.
  5. This switch excels when used exclusively for hoisting applications, seamlessly integrating with transformers on the line.
  6. With a rated current spectrum of 200-400 amps, typically utilizing three mounting holes, and extending to 600-1000A configurations also employing three mounting holes.

Annual Maintenance Recommendations: Inspect these critical components each year:
Meticulously eliminate dirt from conductive parts, contact surfaces, and insulating porcelain bottle surfaces to maintain peak performance.

Conduct thorough checks for any component damage, paying particular attention to the insulating porcelain bottle for cracks or other damage.

Ensure the conductive part's contact surface remains in excellent condition for consistent functionality.


Outdoor Load Break Disconnector with High Isolation Voltage Specifications

Detailed Photos

Outdoor Load Break Disconnector with High Isolation Voltage Specifications
Outdoor Load Break Disconnector with High Isolation Voltage Specifications
Outdoor Load Break Disconnector with High Isolation Voltage Specifications
Outdoor Load Break Disconnector with High Isolation Voltage Specifications


Outdoor Load Break Disconnector with High Isolation Voltage Specifications
Outdoor Load Break Disconnector with High Isolation Voltage Specifications

Outdoor Load Break Disconnector with High Isolation Voltage Specifications
Outdoor Load Break Disconnector with High Isolation Voltage Specifications
Outdoor Load Break Disconnector with High Isolation Voltage Specifications
Outdoor Load Break Disconnector with High Isolation Voltage Specifications
Outdoor Load Break Disconnector with High Isolation Voltage Specifications
Outdoor Load Break Disconnector with High Isolation Voltage Specifications
Outdoor Load Break Disconnector with High Isolation Voltage Specifications
Outdoor Load Break Disconnector with High Isolation Voltage Specifications
Outdoor Load Break Disconnector with High Isolation Voltage Specifications
Outdoor Load Break Disconnector with High Isolation Voltage Specifications
Outdoor Load Break Disconnector with High Isolation Voltage Specifications
Outdoor Load Break Disconnector with High Isolation Voltage Specifications

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Outdoor Load Break Disconnector with High Isolation Voltage SpecificationsOutdoor Load Break Disconnector with High Isolation Voltage Specifications

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier