Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
  • Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
  • Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
  • Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
  • Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
  • Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
Product Description

The (H)GWBEB type outdoor high-voltage isolation switch, often referred to as an isolation disconnect switch, is engineered to perfection for high voltage power transmission and distribution lines operating at 10(12, 15, 24)kV. It seamlessly opens and closes single-phase or three-phase circuits while maintaining voltage presence, ensuring reliability without load interruption.

This switch is crafted for single-phase applications within three-phase line systems, celebrated for its simplicity, cost-efficiency, and user-friendliness. It is available in a range of rated currents: 200, 400, 600, 800, 1000, and 1250 amps. The switch is composed of essential components: a robust base, sturdy post insulators, efficient conductive parts, and a mechanical section. The gate knife structure adeptly facilitates circuit opening and closing, with each phase featuring two conductive blades, enhanced by external compression springs on both sides. By adjusting the spring height, optimal contact pressure is achieved for the gate knife of the switch. This mechanism is operated with precision using an insulated hook stick for effective opening and closing actions and includes a self-locking device for added security.

Working Environment:

The switch is designed for altitudes not exceeding 1000 meters, ensuring optimal performance even at higher elevations.

The ambient temperature should not surpass a maximum of +40°C nor drop below a minimum of -30°C, guaranteeing reliable operation across diverse climatic conditions.

It withstands outdoor wind speeds of up to 35 meters per second, showcasing resilience against nature's forces.

Its seismic strength can endure up to 8 degrees, provided the installation site remains free from frequent severe vibrations.

The installation site must be devoid of gases, chemical deposits, salt mist, dust, dirt, and other explosive or corrosive substances that could compromise the switch's insulation and conductivity.

Note:

WHEN NORMAL USAGE CONDITIONS ARE SURPASSED, USERS ARE INVITED TO CONSULT WITH THE COMPANY FOR SOLUTIONS.

Installation, Use and Adjustment

Pre-installation work

  1. Ensure all parts are free of dust and dirt, meticulously cleaning the insulating porcelain bottle's surface for optimal performance.
  2. Thoroughly scrub the wiring surface of the ground screw to ensure perfect conductivity.
  3. Apply a protective layer of industrial Vaseline to rotating parts and contact areas to preserve functionality and extend lifespan.
  4. Inspect the contact surface and adjust the compression spring's height according to Table II to ensure the contact pressure is accurate and reliable.
  5. This switch is specifically designed for hoisting applications, complementing transformers on the line for enhanced operational efficiency.
  6. With a rated current of 200-400 ampere hours, typically requiring three mounting holes, while 600-1000A applications also utilize three mounting holes.

Conduct an annual inspection of the following switch components to ensure longevity and performance:
Remove dirt from conductive parts, contact surfaces, and the insulating porcelain bottle's surface to maintain pristine condition.

Examine all components for potential damage, paying close attention to the insulating porcelain bottle for any signs of damage or cracks.

Ensure the contact surface of the conductive part remains in excellent condition for uninterrupted functionality.


Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor

Detailed Photos

Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor


Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor

Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor
Custom OEM Load Break Disconnector Isolator Switch High Voltage Outdoor

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications