High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
  • High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
  • High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
  • High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
  • High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
  • High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
Product Description

(H)GWBEB Type Outdoor High-Voltage Isolation Switch: Expertly crafted for 10(12, 15, 24)kV high voltage power transmission and distribution networks, this switch enables the seamless management of single-phase or three-phase circuits without the load, ensuring operational efficiency even under live voltage conditions.

Designed for ultimate reliability in three-phase line systems, this switch stands out for its straightforward design, cost-effectiveness, and user-friendly operation. With rated current options of 200, 400, 600, 800, 1000, and 1250 amps, its robust construction includes a base, post insulators, conductive components, and a meticulously engineered mechanical section. The innovative gate knife mechanism, featuring dual conductive blades with external compression springs, assures optimal contact pressure through adjustable spring height. Operable via an insulated hook stick, it incorporates a secure self-locking feature, epitomizing safety and ease of use.

Working Environment: Ensure your switch operates within the parameters of a conducive environment for peak performance.

Altitude: Safe operation up to 1000 meters above sea level.

Temperature Range: Reliable functionality between a maximum of +40°C and a frigid minimum of -30°C.

Wind Speed: Designed to withstand outdoor wind speeds up to 35 meters per second.

Seismic Intensity: Engineered for stability against seismic activities up to 8 degrees, provided the location is free from regular intense vibrations.

Site Requirements: Choose an installation site devoid of harmful gases, chemical deposits, salt mist, dust, dirt, or other explosive or corrosive substances that could impair the switch's insulation and conductivity.

Note: Personalized solutions available for conditions exceeding standard parameters.

WHEN THE ABOVE NORMAL USE CONDITIONS ARE EXCEEDED, THE USER CAN NEGOTIATE WITH THE COMPANY FOR CUSTOM SOLUTIONS.

Installation, Use, and Adjustment: Comprehensive guidelines for optimal switch functionality.

Pre-installation Work: Essential steps to prepare your switch for installation.

  1. Ensure all parts are immaculate by removing dust and dirt, and carefully polish the insulating porcelain bottle's surface to perfection.
  2. Thoroughly scrub the ground screw's wiring surface to ensure pristine connectivity.
  3. Enhance the longevity of moving parts by applying a protective layer of industrial Vaseline to all rotating and contact areas.
  4. Inspect contact surfaces and adjust the compression spring height to meet the standards in Table II, ensuring optimal contact pressure.
  5. This switch is meticulously designed for hoisting use, synchronized perfectly with transformers in the line.
  6. Rated Current: Adequate mounting options for 200-400 ampere hours, typically requiring three mounting holes, with 600-1000 ampere options following the same configuration.

Regular Maintenance: Annual inspections to ensure continued peak performance.
Maintain the conductive parts, contact surfaces, and insulating porcelain bottles by removing accumulated dirt to preserve optimal function.

Conduct a thorough inspection for any damage, particularly on insulating porcelain bottles for signs of cracks or wear.

Confirm the integrity of all conductive part contact surfaces for uninterrupted conductivity.


High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology

Detailed Photos

High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology


High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology

High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology
High Voltage Outdoor Disconnect Switch with Advanced Load Break Technology

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications