Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introducing the extraordinary (H) RW(F) series, an outdoor high voltage AC drop fuse renowned for its cutting-edge design and unmatched functionality. This exceptional fuse is crafted for outdoor overhead distribution systems with a rated frequency of 50Hz and a versatile rated voltage range of 10kV to 40.5kV. It serves as the ultimate guardian for circuits and electrical equipment, providing reliable protection against overload and short circuit faults in power systems. During normal operations, the fuse remains tautly connected in the power line, ensuring a secure and locked position. However, in the event of a line failure, the fault current swiftly causes the fuse to blow, releasing the movable joint and allowing the fuse tube to drop instantaneously, effectively cutting off the circuit. This ingenious mechanism offers unparalleled safety protection, ensuring the smooth maintenance of both lines and equipment. Furthermore, the load-type fuse is innovatively enhanced with elastic contact and an arc extinguishing cover, enabling it to adeptly open and close load currents within the power system.
Our fuse is engineered to meet stringent technical standards, including GB / T 15166.3 - 2008 high voltage AC fuses - Part 3: injection fuses, and DL / T 640 - 1997 outdoor AC high voltage drop-tested fuses and fuse links ordering technical conditions, guaranteeing top-tier performance and reliability.
Working Environment:
Ambient temperature: from a frosty -40°C to a tropical +40°C;
Relative humidity: daily average not exceeding 95%, with a monthly average under 90%;
Altitude: Perfect for locations with altitudes up to 3000 meters;
Outdoor wind speed: Designed to withstand gusts up to 34 meters per second;
Installation site: Ideal for environments free of fire, explosion hazards, chemical corrosive gases, and ensuring well-ventilated conditions.
Note: Should the above normal use conditions exceed, we invite users to engage in negotiations with our company for tailored solutions.
Technical parameters
Note: Tailored product solutions are available as per user requirements. Our commitment is to deliver excellence.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |