Introducing the ZW32-12 outdoor high voltage vacuum circuit breaker, affectionately referred to as the 'circuit breaker.' This top-tier outdoor distribution switchgear is engineered for a rated voltage of 12kV, delivering a robust three-phase AC of 50Hz. Versatile and efficient, this circuit breaker is adept at managing the interruption and connection of load currents, overload currents, and short circuit currents within the power grid. It excels with advanced overload and short circuit protection capabilities, seamlessly addressing control and measurement needs while providing sophisticated remote control and monitoring functionalities. Its wide-ranging applications include substations, industrial facilities, and mining enterprise distribution systems, offering unmatched control, ideal for environments with frequent operations.
Structural features:
The circuit breaker is crafted with precision, showcasing a three-phase pillar dry design, exemplifying meticulous engineering;
With its fully enclosed design, it ensures superior sealing, exceptional moisture resistance, and anti-condensation properties, ideal for high-temperature and humid regions;
Incorporates state-of-the-art vacuum arc extinguishing technology, guaranteeing outstanding insulation reliability;
Demonstrates flawless opening and closing performance, ensuring safety with no risk of combustion or explosion;
Compact and lightweight, this maintenance-free option promises an impressive lifespan;
Offers operational versatility with manual, electric, or remote control options available;
The operating mechanism is meticulously sealed at the switch box base, effectively safeguarding against outdoor environmental corrosion;
Features a novel, simplistic design with a restless mechanism that ensures reliable dynamic performance, a compact form, and an astounding service life of up to 10,000 cycles.
Main technical parameters:
No |
Name |
Unit |
Data |
|||
1 |
Rated voltage |
kV |
12 |
|||
2 |
Rated current |
A |
630 |
1250 |
||
3 |
Rated frequency |
Hz |
50 |
|||
4 |
Rated insulation level |
1min power frequency withstand voltage |
Dry test |
/ |
42/48(fracture) |
|
Wet test |
34 |
|||||
Secondary circuit to ground |
2 |
|||||
Lightning impulse withstand voltage (peak value) |
75/85(fracture) |
|||||
5 |
Rated short circuit making current (peak value) |
kA |
50 |
63 |
||
6 |
Rated short time withstand current |
kA |
20 |
25 |
||
7 |
Rated peak withstand current |
kA |
50 |
63 |
||
8 |
Breaking times of rated short circuit breaking current |
Times |
30 |
|||
9 |
Rated short circuit duration |
s |
4 |
|||
10 |
Rated operating voltage and rated voltage of auxiliary circuit |
V |
DC220,AC220 ,AC/DC220 |
|||
11 |
Rated operation sequence |
/ |
Off-0.3s-on-off-180s-on-off |
|||
12 |
Rated current of over current trip |
A |
5 |
|||
13 |
Mechanical life |
second |
10000 |
|||
14 |
Allowable wear accumulative thickness of moving and static contacts |
mm |
3 |
|||
15 |
Rated current of over current release |
A |
5 |
|||
16 |
Current ratio of current transformer |
/ |
200/5 400/5 600/5 |
|||
17 |
Contact opening distance |
mm |
9±1 |
|||
18 |
Contact overtravel |
mm |
2±0.5 |
|||
19 |
Average opening speed |
m/s |
1.2±0.3 |
|||
20 |
Average closing speed |
m/s |
0.6±0.2 |
|||
21 |
Opening time |
ms |
≤40 |
|||
22 |
Closing time |
ms |
20~45 |
|||
23 |
Closing bounce time |
ms |
≤2 |
|||
24 |
Asynchrony of three phase closing and opening |
mm |
≤2 |
|||
25 |
Three phase circuit resistance |
μΩ |
≤80 Band isolation≤120 |