Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, a masterpiece of modern electrical engineering, is purpose-built for outdoor overhead distribution networks operating at a frequency of 50Hz and a remarkable voltage range of 10kV (12/15/35/40.5). This indispensable safeguard ensures the protection of circuits and electrical equipment from overloads or short-circuits within power systems. In normal conditions, it remains securely tensioned in the power line, guaranteeing uninterrupted connectivity. Should a fault arise, the smart design swiftly allows the fault current to fracture the fuse, triggering the release of the movable joint. This rapid action causes the fuse tube to drop, thereby ensuring the circuit is decisively disconnected, offering vital safety during maintenance. Enhanced with an elastic contact and an arc extinguishing cover, this load type fuse is unparalleled in efficiently managing the opening and closing of load currents within the power system.
Our fuse is expertly engineered to conform to the stringent technical stipulations of GB / T 15166.3 - 2008 for high voltage AC fuses, specifically Part 3: injection fuses, alongside DL / T 640 - 1997 for outdoor AC high voltage drop-tested fuses. These distinguished standards promise premier performance and steadfast reliability under defined technical conditions.
Working Environment:
This product is adeptly designed to perform optimally across a broad ambient temperature spectrum from a brisk -40°C to a cozy +40°C, ensuring exemplary performance across diverse climatic conditions.
With its capability to tolerate a relative humidity where the daily average does not exceed 95% and the monthly average remains below 90%, this fuse is crafted to thrive in environments with substantial humidity.
It is expertly suitable for altitudes not exceeding 3000 meters, thus accommodating a vast array of geographical settings.
Engineered to withstand formidable outdoor wind speeds up to 34 meters per second, this fuse retains its stability and operational functionality amidst windy conditions.
The installation site must be devoid of fire, explosion risks, and chemical corrosive gases, while ensuring it is well-ventilated, to maintain optimal performance and secure safety.
Note: Should the specified normal usage conditions be surpassed, we encourage users to engage with our company to explore potential solutions, ensuring sustained safety and operational efficiency.
Technical parameters
Note: We proudly offer customizable solutions, crafting products tailored to meet the unique specifications of user requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |