Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) series outdoor high voltage AC drop fuse, commonly referred to as the 'fuse', is designed for optimal performance in outdoor overhead distribution systems. With a rated frequency of 50Hz and a rated voltage scaling from 10kV to 40.5kV, this fuse is the go-to choice for safeguarding circuits or electrical equipment against overloads or short circuit faults. In normal operation, the fuse integrates seamlessly into the power line, maintaining a tensioned state with its movable joint securely locked. Upon a line fault, the fault current triggers the fuse to blow, promptly releasing the joint, causing the fuse tube to drop and disconnect the circuit. This rapid action ensures robust safety protection during line and equipment maintenance. The load type fuse is further enhanced with an elastic contact and arc extinguishing cover, a feature that ensures efficient management of load current within the power system.
The fuse adheres to rigorous technical standards such as GB / T 15166.3 - 2008 for high voltage AC fuses - Part 3: injection fuses, and complies with DL / T 640 - 1997 for outdoor AC high voltage drop-tested fuses, ensuring reliable fuse links ordering technical conditions.
Working Environment:
Ambient temperature ranges from an icy -40°C to a warm +40°C;
Relative humidity: daily average does not surpass 95%, and the monthly average remains below 90%;
The altitude is comfortably capped at 3000 meters;
Designed to withstand outdoor wind speeds up to 34 meters per second;
Installation site: situated away from fire, explosion hazards, corrosive chemical gases, and must be a well-ventilated area.
Note: Should usage conditions exceed the normal parameters outlined, users are encouraged to engage in negotiations with the company for potential accommodations.
Technical parameters
Note: Our company is fully equipped to customize products in alignment with specific user requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |