(H) RW(F) series outdoor high voltage AC drop fuse, masterfully engineered for today's advanced electrical systems, emerges as an outstanding solution for outdoor overhead distribution networks operating at a frequency of 50Hz. With an impressive voltage threshold of 10kV (12/15/35/40.5), this fuse plays a vital role in shielding circuits and electrical equipment from the dangers of overloads or short-circuits in power systems. Under typical conditions, it remains steadfast, tensioned, and securely locked within the power line, guaranteeing uninterrupted connectivity. However, in the event of a fault, the ingenious design permits the fault current to swiftly blow the fuse, triggering the release of the movable joint. This rapid reaction ensures the fuse tube descends swiftly, effectively disrupting the circuit to deliver essential safety during maintenance operations. Augmented with an elastic contact and arc extinguishing cover, this load type fuse excels in smoothly opening and closing the load current within power systems.
Our fuse is meticulously crafted in accordance with stringent technical benchmarks, such as GB / T 15166.3 - 2008 for high voltage AC fuses, Part 3: injection fuses, and DL / T 640 - 1997 for outdoor AC high voltage drop-tested fuses. These standards assure unparalleled performance and reliability within specified technical parameters.
Working Environment:
This product is crafted to perform reliably across a broad ambient temperature span, from a frosty -40°C to a balmy +40°C, thus ensuring robust functionality across diverse climates.
It accommodates a relative humidity tolerance where the daily average remains below 95% and the monthly average is under 90%, making it suitable for high-humidity conditions.
This fuse is adept for altitudes not exceeding 3000 meters, thus catering to various geographical terrains.
Expertly designed to withstand outdoor wind speeds up to 34 meters per second, this fuse retains its stability and operational efficiency even in gusty environments.
Installation sites should be clear of fire, explosion risks, and chemically corrosive gases, and should be well-ventilated to ensure peak performance and safety.
Note: If the stipulated normal use conditions are surpassed, we encourage users to engage with us to explore tailored solutions that ensure sustained safety and operational efficacy.
Technical parameters
Note: We provide customizable solutions, offering products precisely tailored to meet unique user specifications.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |