Customization: | Available |
---|---|
Breaking Capacity: | 12kv/24kv/40.5kv |
Type: | Current Fuse |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
(H) RW(F) Series: This exceptional outdoor high voltage AC drop fuse, fondly referred to as "fuse," is meticulously engineered for optimal performance in outdoor overhead distribution systems. It boasts a rated frequency of 50Hz and accommodates a rated voltage of 10kV (12/15/35/40.5), serving as a steadfast guardian against overloads or short circuit faults. Seamlessly integrated into the power line, this fuse remains in a tensioned state, secured by a robust movable joint. Upon encountering a fault, the resultant fault current expertly triggers the fuse to blow, releasing the movable joint and swiftly dropping the fuse tube to sever the circuit. This crucial action ensures unparalleled safety protection for line and equipment maintenance. Enhanced with an elastic contact and arc extinguishing cover, the load type fuse is adept at opening and closing load currents within the power system, surpassing ordinary types with ease.
Our fuses meet and exceed rigorous technical standards, including GB / T 15166.3 - 2008 High Voltage AC Fuses - Part 3: Injection Fuses, DL / T 640 - 1997 Outdoor AC High Voltage Drop Tested Fuses, and Fuse Links Ordering Technical Conditions. Trust in our commitment to quality and precision.
Working Environment:
Ambient Temperature: Designed to perform flawlessly in a wide range from a chilling -40°C to a scorching +40°C;
Relative Humidity: Engineered for resilience, with a daily average not exceeding 95% and a monthly average not exceeding 90%;
Altitude Capability: Functioning at altitudes up to 3000m with consistent reliability;
Wind Tolerance: Capable of withstanding outdoor wind speeds up to 34 meters/second, ensuring steadfast performance;
Installation Site Requirements: Optimal in environments free from fire, explosion hazards, and chemical corrosive gases, with a well-ventilated setting.
Note: Should your operational conditions exceed these specifications, we invite you to engage in a dialogue with us to explore tailored solutions.
Technical Parameters
Note: Our company is dedicated to customization, delivering products that align perfectly with your specific requirements.
Model |
Voltage |
Current |
Rated maximum
breaking current |
1min power frequency dry withstand
voltage |
1min power frequency wet withstand
voltage |
Rated lightning impulse withstand
voltage |
Opening and closing
load current |
XS-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
XS-15/100(200) |
15 |
||||||
PD-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
PD-15/100(200) |
15 |
||||||
(H)RW3-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW3-12/100(200) |
12 |
||||||
(H)RW4-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW4-12/100(200) |
12 |
||||||
(H)RW7-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW7-12/100(200) |
12 |
||||||
(H)RW10-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW10-12/100(200) |
12 |
||||||
(H)RW10-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW10-12F/100(200) |
12 |
||||||
(H)RW11-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
! |
(H)RW11-12/100(200) |
12 |
||||||
(H)RW11-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)RW11-12F/100(200) |
12 |
||||||
(H)RW12-10/100(200) |
10 |
100 (200) |
6.3 (12.5) |
45 |
30 |
105 |
/ |
(H)RW12-12/100(200) |
12 |
||||||
(H)RW12-15/100(200) |
15 |
||||||
(H)PRWG1-10F/100(200) |
10 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
10 |
(H)PRWG1-12F/100(200) |
12 |
||||||
(H)RW33-12/100(200) |
12 |
100 (200) |
6.3 (12.5) |
42 |
30 |
75 |
/ |
(H)RW33-15/100(200) |
15 |
||||||
(H)RW5-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)RW10-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |
|||||||
(H)PRWG2-35/100(200) |
35 |
100 (200) |
6.3 (12.5) |
95 |
86 |
185 |
/ |
40.5 |