Current Limiting Fuse with High Voltage Drop-out Protection Capabilities

Product Details
Customization: Available
Breaking Capacity: 12kv/24kv/40.5kv
Type: Current Fuse
Still deciding? Get samples of US$ 30/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Current Limiting Fuse with High Voltage Drop-out Protection Capabilities
  • Current Limiting Fuse with High Voltage Drop-out Protection Capabilities
  • Current Limiting Fuse with High Voltage Drop-out Protection Capabilities
  • Current Limiting Fuse with High Voltage Drop-out Protection Capabilities
  • Current Limiting Fuse with High Voltage Drop-out Protection Capabilities
  • Current Limiting Fuse with High Voltage Drop-out Protection Capabilities
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Company Profile
Overview

Basic Info.

Model NO.
(H)RW(F)
Usage
High Voltage
Shape
According to Customer Requirements
Fusing Speed
FF
Fusing Device
According to Customer Requirements
Standard
IEC/ANSI/IEEE
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
50.00cm * 30.00cm * 25.00cm
Trademark
CHBEB
Origin
China
HS Code
8535100000
Production Capacity
1000 PCS/Month

Product Description

Current Limiting Fuse with High Voltage Drop-out Protection Capabilities
Current Limiting Fuse with High Voltage Drop-out Protection CapabilitiesCurrent Limiting Fuse with High Voltage Drop-out Protection CapabilitiesCurrent Limiting Fuse with High Voltage Drop-out Protection CapabilitiesCurrent Limiting Fuse with High Voltage Drop-out Protection CapabilitiesCurrent Limiting Fuse with High Voltage Drop-out Protection CapabilitiesCurrent Limiting Fuse with High Voltage Drop-out Protection CapabilitiesCurrent Limiting Fuse with High Voltage Drop-out Protection CapabilitiesCurrent Limiting Fuse with High Voltage Drop-out Protection CapabilitiesCurrent Limiting Fuse with High Voltage Drop-out Protection CapabilitiesCurrent Limiting Fuse with High Voltage Drop-out Protection Capabilities
Product Description

(H) RW(F) series outdoor high voltage AC drop fuse is an ingeniously engineered marvel, crafted to enhance and modernize electrical systems. It stands as the ideal solution for safeguarding outdoor overhead distribution networks operating at a frequency of 50Hz, with an impressive voltage range of 10kV (12/15/35/40.5). This indispensable component provides robust protection against potential overloads or short-circuits, effectively safeguarding circuits and critical electrical equipment within power systems. Under standard operational conditions, it remains tensioned and securely anchored in the power line, ensuring seamless connectivity and uninterrupted service. In the event of a fault, its highly responsive design allows the fault current to promptly activate the fuse, resulting in the release of the movable joint. This swift and decisive action causes the fuse tube to drop instantaneously, effectively severing the circuit and offering paramount safety during maintenance procedures. Enhanced with an elastic contact and an arc extinguishing cover, this load type fuse is distinguished by its exceptional capability to efficiently open and close the load current within the power system.

Our fuse is meticulously crafted to adhere to stringent technical standards, including GB / T 15166.3 - 2008 for high voltage AC fuses, Part 3: injection fuses, and DL / T 640 - 1997 for outdoor AC high voltage drop tested fuses. These rigorous standards ensure that our fuse delivers top-tier performance and unmatched reliability under precisely specified technical conditions.

Working Environment:

This product is engineered to perform robustly across a wide ambient temperature spectrum, from a chilly -40°C to a warm +40°C, ensuring its steadfast performance in diverse climatic conditions.

With an impressive relative humidity tolerance, where the daily average does not exceed 95% and the monthly average remains below 90%, this fuse is specifically designed to thrive even in high humidity environments.

Our fuse is designed to be suitable for altitudes not exceeding 3000 meters, making it adaptable to a wide range of geographical locations and conditions.

Engineered to withstand outdoor wind speeds of up to 34 meters per second, this fuse maintains its stability and functionality, even in challenging and windy conditions.

The installation site should be free from fire, explosion hazards, and chemical corrosive gases, and must be well-ventilated to ensure the fuse's optimal performance and safety.

Note: If the prescribed normal use conditions are exceeded, we invite users to engage in discussions with our company to explore potential solutions, ensuring continuous safety and operational efficiency.

Detailed Photos

Current Limiting Fuse with High Voltage Drop-out Protection Capabilities

Current Limiting Fuse with High Voltage Drop-out Protection Capabilities
Current Limiting Fuse with High Voltage Drop-out Protection Capabilities
Current Limiting Fuse with High Voltage Drop-out Protection Capabilities

Product Parameters

Technical parameters

Note: We provide customizable solutions, offering products meticulously tailored to meet specific user requirements and preferences.

Model


Rated

 

 

Voltage
kV


Rated

 

 

Current
A

 

Rated

maximum

 

 

breaking current
kA

 

1min power

frequency

dry

withstand

 

voltage
(valid value)
kV

 

1min power

frequency

wet

withstand

 

voltage
(valid value)
kV

 

Rated

lightning

impulse

withstand

 

voltage
(peak)
kV

Opening

and

closing

 

 

load current
A

XS-12/100(200)

12

100

(200)

6.3

(12.5)

42

30

75

/

XS-15/100(200)

15

PD-12/100(200)

12

100

(200)

6.3

(12.5)

42

30

75

/

PD-15/100(200)

15

(H)RW3-10/100(200)

10

100

(200)

6.3

(12.5)

42

30

75

/

(H)RW3-12/100(200)

12

(H)RW4-10/100(200)

10

100

(200)

6.3

(12.5)

42

30

75

/

(H)RW4-12/100(200)

12

(H)RW7-10/100(200)

10

100

(200)

6.3

(12.5)

42

30

75

/

(H)RW7-12/100(200)

12

(H)RW10-10/100(200)

10

100

(200)

6.3

(12.5)

42

30

75

/

(H)RW10-12/100(200)

12

(H)RW10-10F/100(200)

10

100

(200)

6.3

(12.5)

42

30

75

10
(200)

(H)RW10-12F/100(200)

12

(H)RW11-10/100(200)

10

100

(200)

6.3

(12.5)

42

30

75

!

(H)RW11-12/100(200)

12

(H)RW11-10F/100(200)

10

100

(200)

6.3

(12.5)

42

30

75

10
(200)

(H)RW11-12F/100(200)

12

(H)RW12-10/100(200)

10

100

(200)

6.3

(12.5)

45

30
(38)

105

/

(H)RW12-12/100(200)

12

(H)RW12-15/100(200)

15

(H)PRWG1-10F/100(200)

10

100

(200)

6.3

(12.5)

42

30

75

10
(200)

(H)PRWG1-12F/100(200)

12

(H)RW33-12/100(200)

12

100

(200)

6.3

(12.5)

42

30

75

/

(H)RW33-15/100(200)

15

(H)RW5-35/100(200)

35

100

(200)

6.3

(12.5)

95

86

185

/

40.5

(H)RW10-35/100(200)

35

100

(200)

6.3

(12.5)

95

86

185

/

40.5

(H)PRWG2-35/100(200)

35

100

(200)

6.3

(12.5)

95

86

185

/

40.5

Certifications

Current Limiting Fuse with High Voltage Drop-out Protection Capabilities

Company Profile

Current Limiting Fuse with High Voltage Drop-out Protection CapabilitiesCurrent Limiting Fuse with High Voltage Drop-out Protection Capabilities

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier