Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design

Product Details
Customization: Available
Type: 10kv/12kv/15kv
Structure: According to Customer Requirements
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

OEM Services
The supplier provides OEM services for popular brands
Quality Assurance
The supplier provides quality assurance
Private Mold
The supplier has private mold
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
to see all verified strength labels (20)
  • Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
  • Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
  • Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
  • Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
  • Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
  • Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
Overview

Basic Info.

Model NO.
(H)GWBEB
Installation
Outdoor High-voltage
Operation
Manual/Electric/Pneumatic/Hydraulic
Grounding Mode
According to Customer Requirements
Movement Mode
According to Customer Requirements
Number of Poles
According to Customer Requirements
Grounding
According to Customer Requirements
Series
Two
Run
According to Customer Requirements
Switching Mode
According to Customer Requirements
Common Model
Gw9
Structure of Operating
According to Customer Requirements
Certification
ISO, RoHS, CE
Brand
Chbeb
Customizable
OEM/According to Customer Requirements
Transport Package
Standard Shipping Packing
Specification
45*55*38mm
Trademark
CHBEB
Origin
China
HS Code
853530900
Production Capacity
5000 PCS/Quarter

Product Description

Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
Product Description

The (H)GWBEB type outdoor high-voltage isolation switch, affectionately known as an isolation disconnect switch, is meticulously crafted to perform seamlessly on 10(12, 15, 24)kV high voltage power transmission and distribution lines. Its primary function is to adeptly open and close single-phase or three-phase circuits without engaging the load, all while maintaining voltage presence.

This versatile switch is specifically designed for single-phase operations within three-phase line systems. It stands out due to its streamlined structure, remarkable affordability, and effortless usability. Offering a range of rated currents—200, 400, 600, 800, 1000, and 1250 amps—this switch is a blend of a robust base, reliable post insulators, conductive components, and a meticulously engineered mechanical section. It employs a gate knife structure to efficiently manage the circuit operations. Each phase's gate knife is a duo of conductive blades, bolstered by external compression springs on each side, allowing for precise adjustment of contact pressure simply by modifying the spring height. Its operation is simplified through an insulated hook stick, making opening and closing maneuvers easy, and it comes equipped with a dependable self-locking device.

Working Environment:

It thrives at altitudes not exceeding 1000 meters;

This switch operates seamlessly within an ambient temperature range from a cool -30°C to a warm +40°C;

Designed to withstand outdoor wind speeds up to 35 meters/second;

Endures seismic intensities up to 8 degrees, provided the installation environment is free from frequent intense vibrations.

The installation area must be devoid of gases, chemical deposits, salt mist, dust, dirt, or any other explosive or corrosive substances that could significantly impair the switch's insulation and conductivity.

Note:

SHOULD THE USE CONDITIONS SURPASS THE ABOVE PARAMETERS, USERS ARE ENCOURAGED TO DISCUSS POSSIBLE SOLUTIONS WITH THE COMPANY.

Installation, Use and Adjustment

Pre-installation work

  1. Begin by meticulously removing any dust and dirt from the components, ensuring the insulating porcelain bottle is carefully polished to perfection.
  2. Diligently clean the wiring surface of the ground screw to ensure optimal performance.
  3. Apply a protective layer of industrial Vaseline to all rotating parts and contact regions to maintain smooth operation.
  4. Thoroughly examine the contact surface and adjust the compression spring height to ensure the contact pressure aligns with Table II's specifications.
  5. This switch is exclusively designed for hoisting applications and is intended to be used in tandem with the transformer along the line.
  6. With a rated current capacity of 200-400 ampere hours, this switch generally requires only three mounting holes. For currents of 600-1000A, three mounting holes are also utilized.

Conduct annual inspections of the following switch components to maintain peak performance:
Carefully eradicate any dirt from the conductive parts, contact surfaces, and insulating porcelain bottles' surface.

Inspect all components vigilantly for any signs of damage, focusing especially on the insulating porcelain bottle for any damage or cracks.

Ensure the contact surface of the conductive part remains impeccable.


Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design

Detailed Photos

Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design


Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design

Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design
Medium Voltage Load Break Disconnector with Outdoor Isolator Switch Design

Product Parameters

The main technical parameters

Table I

Model

Rated voltage
kV

 

Rated current
A

kA

 

10 seconds thermal stable current
kA

peak

Valid values

 

(H)GW

 

10

12

15

200

5

9

5

400

21

15

10

600

35

25

14

630

35

25

14

800

35

25

14

1000

50

35

20

Contact force parameters

Table II

Model

Rated current(A)

contact pressure(kgf)

(H)GW

5

9

21

15

35

25

35

25

35

25

50

35

Certifications

Medium Voltage Load Break Disconnector with Outdoor Isolator Switch DesignMedium Voltage Load Break Disconnector with Outdoor Isolator Switch Design

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier